![Gree GVA24AL-K3NNC7A/I Service Manual Download Page 85](http://html1.mh-extra.com/html/gree/gva24al-k3nnc7a-i/gva24al-k3nnc7a-i_service-manual_2260413085.webp)
Service Manual
82
Installation and Maintenance
Procedure
Steps
10. Remove 4-way valve assy
11. Remove compressor
4-way valve assy
compressor
foot nuts
Unsolder the welding joints connecting the
4-way valve assy with capillary sub-assy,
compressor and condenser; remove the 4-way
valve.
Note:
Before unsoldering the welding joint, wrap
the 4-way valve with a wet cloth completely
to avoid damage to the valve caused by high
temperature.
Remove 3 foot nuts on compressor, and then
remove the compressor.
Note:
Protect the ports of discharge pipe and suction
pipe to avoid foreign objects to enter it.