DC Inverter U-match Series Duct Type Unit
49
1) Indoor side
Take off the electric box cover from the sub-assembly of electric box.
Then connect the wires. Connect the connection wires of indoor unit
according to the corresponding marks. (Expect for GUD125PH/B-S,
GUD125PHS/B-S, GUD140PH/B-S, GUD140PHS/B-S,
GUD160PH/B-S, GUD160PHS/B-S).
Only for GUD125PH/B-S, GUD125PHS/B-S, GUD140PH/B-S,
GUD140PHS/B-S, GUD160PH/B-S, GUD160PHS/B-S.
2) Outdoor side
Remove the big handle/front panel of the outdoor unit and insert one
end of the communication cord and the power cord to the terminal
board.
For the connection wires of DRED module, it’s suggested to use
rubber cord that is pursuant to 57 in IEC 60245 lines. If the connection
wires use H05VV-F or other conducting wires that are unsuitable for
outdoors, we suggest user should install the connection wire in
wire-leading ducts that are separated from rain and violet ray.
DRED module should be installed indoors or inside an enclosed
space that can prevent rain and violet ray.