3. Remove the pre-installed drain cap from the unit,

If you have selected the drainage hose, insert it

into the drainage outlet.
Drain the water into the small pan or a suitable place.
Once draining is complete,re-install drain cap.
Press ON/OFF button to restart the unit.

power cord hooks

Drainage port

screws

direction of power cord hooks is downward

Wind the power cord around the power cord
hooks.

1.

Removing Collected Water

2. Use a small pan or  move the unit to a suitable pl-

1

Preparation before Installation 

Install Power cord Hooks

4.
5.
6.

Water can be automatically emptied into a floor drain
by attaching 14mm inner diameter hose (not included). 

Remove the continuous drain cap 1 by turning it
counter clockwise then remove the rubber stopper
2 from the spout.

There are 2 ways to remove collected water:

Notice

    ace to drain the water.

Turn the unit off and unplug from the electrical

    outlet.

1

Use the drainage option from the lower hole.

In Cool, Dry or Heat mode operating, the condens-
ation water will be drained to the chassis.

When the chassis is full with water, the buzzer will 
give out 8 sounds and "H8" is displayed to remind 
user to discharge water, the unit will turned off 2min 
latter, and all buttons are invalid.
To empty the chassis, please follow the instructions 
bellow.   

1.

Assemble the power cord hooks at the back of

2

Use the continuous drainage option from the 
middle hole

the unit with screws (the direction of  power cord 
hooks is as shown in following fig). 

direction of power cord hooks is upward

Summary of Contents for GPC12AO-K5NNA1A

Page 1: ...re operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or visit www gree com or send an email to global gree com cn for the electronic version GPH12AO K5NNA1A GPC12AO K5NNA1A Model Owner s Manual Original Instructions Local air conditioner ...

Page 2: ...play Screen Installation Function Introduction for Combination Buttons Replacement of Batteries in Remote Controller Maintenance Clean and Maintenance Malfunction Malfunction analysis Disassembly of Heat Discharge Pipe Installation of Heat Discharge Pipe Attached Sheet Electric Schematic Diagram Installation Precaution Removing Collected Water Operation Test 3 4 Specialist s Manual 1 2 6 7 8 Prepa...

Page 3: ...reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate risk of property damage If it needs to install move or maintain the air conditioner please contact dealer or local service center to conduct it at first Air conditioner must be installe...

Page 4: ... the EU To prevent possible harm to the environm ent or human health from uncontrolled in a room with a floor area larger than 11m The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas app liance or an operating electric heater The appliance shall be stored in a well ventilated area where the room size corresponds to the ro...

Page 5: ...then contact local dealer When nobody is taking care of the unit please turn it off and remove the power plug or disconnect power Prohibit operating the unit in the bathroom or laundry room Far away from fire source inflammable and explosive objects Children and disabled people are not allowed to use the portable room air conditioner without supervision Keep children from playing or climbing on th...

Page 6: ...sconnect power immediately and contact dealer Avoid direct sunshine Please put the air conditioner at smooth and flat ground for operation to avoid noise and vibration This air conditioner is equipped with castors Castors should slide The appliance is for indoor use only The appliance must be positioned so that the plug is accessible The air conditioner must be operated within the temperature rang...

Page 7: ...e 1 2 3 2 3 4 5 6 7 5 6 FAN OPER 7 Sleep Timer 8 Health WiFi 10 9 Remote controller Some installation accessories can t be discarded Filter Air inlet On Off Fan Mode Swing Notice 1 Controller panel Guide louver ...

Page 8: ...n control panel the air conditioner will give out a sound Meanwhile corresponding indicator on control panel will be bright Under OFF status dual 8 nixie tube on control panel won t display Under ON status dual 8 nixie tube on control panel will display set temperature under cooling mode and Heating mode Cool Heat Unit only while it won t display under other modes Cool Under this mode cooling mode...

Page 9: ...orescent lamp in the same room may interfere with transmission of the signal Do not leave the remote control in direct sunlight or ne ar a heater Protect the remote control from moisture and shock Set time TIMER ON TIMER OFF Light Up down swing Child lock Set temperature WiFi function Indoor ambient temp Outdoor ambient temp How to use the remote controller Point the remote control toward the Sign...

Page 10: ...ress this button to go into the Sleep operation mode Press it again to cancel this function This function is available in COOL HEAT Only for models with heating function mode to maintain the most co mfortable temperature for you Timer button Under ON status press this button to set timer OFF Under OFF status press this button to set timer ON Press this button once and the characters of HOUR ON OFF...

Page 11: ...tion buttons Temperature display switchover function Under OFF status press and Mode buttons simultaneously to switch temperature display betw een C and F using the remote controller Replace new batteries of the same model when replace ment is required When you don t use remote controller for a long time please take out the batteries The batteries contain materials which are hazardous to the envir...

Page 12: ...e is very dirty such as grease please use neutral abluent to wipe it Clean filter Remove the filter Press the clasp as shown in the fig and then remove the filter Disconnect power supply Clean filter and outer case Remove dust and sundries on the air conditioner Eliminate accumulated water in chassis refer to the section of Drainage way for details Check whether window bracket is damaged or not If...

Page 13: ...it will stop blo wing fan after reaching set temperature Whether heating mo de is started up just now In order to prevent cold air air conditioner will delay for a while to be started up which is the normal phenomenon ature can t be adjusted It s the normal pheno menon Air conditioner is defrosting After de frosting is finished it will resume operation Whether evaporator is defrosted obser ve it b...

Page 14: ...lectric safety regulations when 4 uctions shall contain the substance of the following grounding wire of power socket 5 Be sure to cut off the power supply before proce eding any work related to electricity and safety 6 Do not put through the power before finishing in stallation 7 The air conditioner is first class electric appliance It must be properly grounding with specialized gr If the supply ...

Page 15: ...onge B Sponge A Window adapter bottom Notice Window adapter Joint A Check if the accessories are available before insta llation Heat discharge pipe Drain connector Power cord hooks Screws Window adapter bottom Extension panel Adjustment panel Window kit Window panel Exhaust cover Joint E Joint H Joint D Plastic Cover Cross screwdriver Straight screwdriver Saw Guge Scissors Pencil FAN OPER Fan Swin...

Page 16: ...e the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout There are 2 ways to remove collected water Notice ace to drain the water Turn the unit off and unplug from the electrical outlet 1 Use the drainage option from the lower hole In Cool Dry or Heat mode operating the condens ation water will be drained to the chassis When the chassis is full w...

Page 17: ...on t prolong the pipe or connect it with other heat discharge pipe In order to improve cooling efficiency the heat disch arge pipe should be as short as possible and flat without curve to ensure smooth heat discharge When using continuous drainage option from the middle hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing po...

Page 18: ...se malfunction Window adapter bottom into the two ends of heat discharge pipe Connect Window adapter top to Window adapter bottom Joint A Heat discharge pipe Window adapter top Window adapter bottom 3 2 1 Attach the insect guard net to the window panel Optional 1 Installation in a double window Attach the window panel to the window stool Make sure that the exhaust cover is attached to the window p...

Page 19: ...Slide the adjustment and extension panels to fit 980mm Use the window panel and the adjustme nt panel Adjustment panel 3 Secure the window panel to the window sill with screws Extension panel Adjustment panel 1 Open the window sash and place the window The window panel cannot be installed in windows less than 20 5 520mm wide as you will be una ble to shut the exhaust cover panel on the window sill...

Page 20: ...nd to the side of sash 20 5 520mm 1 Open the window sash and place the window The window panel cannot be installed in windows less than 20 5 520mm high as you will be unable to shut the exhaust cover panel on the window frame 2 Secure the window panel to the window frame 1 Attach the insect guard net to the window panel Sponge A 3 Cut Window panel Install the window panel into the window frame Mak...

Page 21: ...ndow sash securely against the Window panel Bracket 9 Insert joint A of heat discharge pipe into the groo ve until you hear a sound 7 Joint A Heat discharge pipe Stuff the foam seal B between the glass and the window to prevent air and insects from getting into the room Connect Window adapter top to Window ada pter bottom Window adapter top Window adapter bottom 10 8 Window adapter bottom Window a...

Page 22: ...t a hole to install joint D and joint E tightly Inside Outside Joint E Joint D 4 3 Install the other side of heat discharge pipe clock wise into joint D Joint D Groove joint A Insert joint A of heat discharge pipe into the groo ve until you hear a sound Groove joint A Joint A Joint D Heat discharge pipe Window adapter top Window adapter bottom Rotate joint A and joint D and Window adapter top Wind...

Page 23: ...e window adapter Pull out and remove the window adapter by pushing down two PUSH markings and slide and close the exhaust cover in the window panel Optional Joint Joint H 1 2 window Remove joint A Press the clasp and lift joint A upwards to remove it Remove joint F remove joint F from joint H Disassembly for installation in window Remove joint A Press the clasp and lift joint A upwards to remove i...

Page 24: ...RD AP4 M4 RD C1 SA M2 YEGN M1 YEGN PE PE RD CAP CAP BN BN RD ROOM TEMP SENSOR RT1 TUBE TEMP SENSOR OUTTUBE TEMP SENSOR RT3 VALVE 4 WAY 4YV WATER MOTOR YEGN RECEIVER BOARD POWER L N BN BK BU WH YEGN GN N2 WATER AP1 MAIN BOARD AC L K201 C COMP COMP R M DISP1 AP2 COMP FAN DISPLAY BOARD WIFI MODULE STEPPING MOTOR WATER LEVEL SWITCH C3 DOWN FAN MOTOR C2 UP FAN MOTOR GPC12AO K5NNA1A The Electric schemat...

Page 25: ... fire extinguisher No ignition sources If any hot work is to be conducted on the refrige ration equipment or any associated parts approp riate fire extinguishing equipment shall be available to hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area No person carrying out work in relation to a refrig eration system which involves exposing any pipe work shall use any sources o...

Page 26: ... be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be rem oved extinguished If a leakage of refrigerant is found which requires br azing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak For ap pliances containing flamma...

Page 27: ... and that ventilation is available Specialist s Manual Decommissioning a Become familiar with the equipment and its ope ration Isolate system electrically Before attempting the procedure ensure that b c Before carrying out this procedure it is essential that the technician is completely familiar with the equipm ent and all its detail It is recommended good practice that all refrigerants are recove...

Page 28: ...ing the equipment that is at hand and shall be suitable for the recovery of all the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed ensure that they have been evacuated to an accepta couplings and in good condition Before using the re covery machine check that it is in satisfactory w...

Page 29: ...600005062054 GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn Web www gree com ...

Reviews: