background image

When COOL or DRY is running, condensate will drain to water tank.When water tank is filled buz-
zer will sound 8 timers for warn, water tank green indicated light on panel on with H8 displayed on

of condensate and fix drainage pipe fixing clamp as shown in following figure. The unit will resume
running when water filled protect released and compressor stops for 3 minutes.

display window and whole unit stop running. Plug out plug on drainage hose and take off the hose from
fixing clamp, then drain out water in tank. After that,plug the pipe plug onto pipe to prevent leakage

Install of drainage hose (as shown in following figure):
Note: Drainage hose must be installed before using otherwise block of drain may occur

and affects normal run of unit.

Drain Hose included:

Install Drain Hose

1. Remove drain cap from drain port.

Drain Cap

2. Attach one end of the drain hose to the drain port with the clamp. See Drain Hose graphic.

3. Insert the rubber plug into the other end of the drain hose and secure with clip. See Drain Hose graphic.

4. Attach the drain hose clamp to the back panel of the air conditioner near the drain port with the screw

provided.

A. Drain port

B. Drain cap

A

B

Drain hose

Rubber plug

Screw

DRAINAGE METHOD

- 11

 

-

Drain hose clip

Drain hose Clamp

Summary of Contents for GPC08AH-A3NNC3B

Page 1: ...NNC3B MODEL Change for Life Portable Air Conditioner Owner s Manual Residential Air Conditioners Thank you for choosing Residential manual carefully before operation and retain it for future reference...

Page 2: ...AT EXHAUST HOSE 13 MAINTENANCE 15 Names and functions of wireless remote control 7 Guide for operation General operation 9 MALFUNCTION ANALYSIS 16 SAFE NOTE AND NOTICE 17 AFTER SALES SERVICE 18 Functi...

Page 3: ...Thank you for your selection please read this instruction carefully before operating and keep it for consultation...

Page 4: ...the unit This instruction is only for reference the specification parameters are subject to be changed without notice Under function of fan motor indoor airflow changed into cooled air through evapor...

Page 5: ...idifier remember to take off heat discharge pipe from unit and install it onto unit when the unit is used as air conditioner Since partial indoor air will be heated as heat air and discharged to outsi...

Page 6: ...Rear Air outlet vent Upper air inlet grille Lower air inlet grille Control panel Guide louver Swing louver Wheel Power Filters Remote conrtoller box cord Front STRUCTURE 3...

Page 7: ...ts to prevent creep age leaded by mangled wire Circuitry must be installed and fixed by professional personnel following te national wiring regulations Creepage protect switch with enough capa Place t...

Page 8: ...7 When it twinkling that means the water in the tank is full We should drain off the water Panelcontrol l 3 MODE In the state of running press the key to enter the mode of COOL DEHUMIDIFY FAN 4 Fan s...

Page 9: ...e displayed and is not adjusable Environmental temperature Usage environmental temperature of this unit is 16 35 1 Install heat discharge pipe well select a location near door and window connect the h...

Page 10: ...ep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available By pressing this key you may select AUTO FAN...

Page 11: ...rs T ON and H will flash for 5 seconds Within 5 seconds you may make one press of this key to complete the setting and send the message If the setting is valid the set time will be displayed for 2 sec...

Page 12: ...ion When AUTO RUN mode is selected the setting temperature will not be displayed on the LCD the unit will be in accordance with the room temp automatically to select the suitable running method and to...

Page 13: ...eries If the wireless remote control will not be used for a long time please otherwise it can cause the malfunction of the wireless remote control take them out and don t let the leakage liquid damage...

Page 14: ...plug the pipe plug onto pipe to prevent leakage Install of drainage hose as shown in following figure Note Drainage hose must be installed before using otherwise block of drain may occur and affects n...

Page 15: ...aust adapter 3 Twist clockwise to lock hose into place 4 Insert the other end of the flexible exhaust hose into the window exhaust adapter 5 Twist clockwise to lock hose into place A Rubber plug B Dra...

Page 16: ...installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown in figure When installing it on wall height of h...

Page 17: ...e to be bent please install it by considering Wrong installation is shown in following figure If the pipe is following dimension bent too much it would easily cause malfunction 14 ACCESSORIES AND INST...

Page 18: ...s Mobile AC Warning Cleanair filter Please soak the cloth by warm whose temperature is lower than 40 104 F or soap water or water with proper cleaner and wipe the dirty part on unit slightly after the...

Page 19: ...2 Replace the powerplug orsocket 3 Ask for the maintenance man to replace the fuse 1 Thisis the normalphenomenon 2 Unit is running indefrosting operation it will resume running inoriginal operationaft...

Page 20: ...t climb on the unit or place something on it for drop may occur and le ading malfunction Don t let wind blows to human directly for long time for it is not good for health The unit should leave TV for...

Page 21: ...ronic waste can be disposed of at least free of charge to the user b When buying a new product the retailer will take back the old product at least free of charge c The manufacturer will take back the...

Page 22: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66166072...

Reviews: