When COOL or DRY is running, condensate will drain to water tank.When water tank is filled buz-
zer will sound 8 timers for warn, water tank green indicated light on panel on with H8 displayed on
of condensate and fix drainage pipe fixing clamp as shown in following figure. The unit will resume
running when water filled protect released and compressor stops for 3 minutes.
display window and whole unit stop running. Plug out plug on drainage hose and take off the hose from
fixing clamp, then drain out water in tank. After that,plug the pipe plug onto pipe to prevent leakage
Install of drainage hose (as shown in following figure):
Note: Drainage hose must be installed before using otherwise block of drain may occur
and affects normal run of unit.
Drain Hose included:
Install Drain Hose
1. Remove drain cap from drain port.
Drain Cap
2. Attach one end of the drain hose to the drain port with the clamp. See Drain Hose graphic.
3. Insert the rubber plug into the other end of the drain hose and secure with clip. See Drain Hose graphic.
4. Attach the drain hose clamp to the back panel of the air conditioner near the drain port with the screw
provided.
A. Drain port
B. Drain cap
A
B
Drain hose
Rubber plug
Screw