GREE hotovoltaic Multi VRF for North America
103
Error Code
Content
Error Code
Content
Fn
Malfunction of inlet tube temperature
sensor of mode exchanger
JL
Protection because high pressure is too
low
b1
Malfunction of outdoor ambient
temperature sensor
JE
Oil-return pipe is blocked
b2
Malfunction of defrosting temperature
sensor 1
JF
Oil-return pipe is leaking
b3
Malfunction of defrosting temperature
sensor 2
P0
malfunction of driving board of
compressor (uniform)
b4
Malfunction of liquid temperature
sensor of sub-cooler
P1
Driving board of compressor operates
abnormally (uniform)
b5
Malfunction of gas temperature sensor
of sub-cooler
P2
Voltage protection of driving board
power of compressor (uniform)
b6
Malfunction of inlet temp sensor of
gas-liquid separator
P3
Reset protection of driving module of
compressor
b7
Malfunction of outlet temp sensor of
gas-liquid separator
P4
Drive PFC protection of compressor
b8
Malfunction of outdoor humidity
sensor
P5
Over-current protection of inverter
compressor
b9
Malfunction of gas temperature sensor
of heat exchanger
P6
Drive IPM module protection of
compressor
bA
Malfunction of oil-return temperature
sensor 1
P7
Malfunction of drive temperature
sensor of compressor
bH
Clock of system is abnormal
P8
Drive IPM high temperature protection
of compressor
bE
Malfunction of inlet tube temperature
sensor of condenser
P9
Desynchronizing protection of inverter
compressor
bF
Malfunction of outlet tube temperature
sensor of condenser
PA
Malfunction of drive storage chip of
compressor
bJ
High-pressure sensor and
low-pressure sensor are connected
reversely
PH
High-voltage protection of
compressor’s drive DC bus bar
bP
Malfunction of temperature sensor of
oil-return 2
PC
Drive current detection circuit
malfunction of compressor
bU
Malfunction of temperature sensor of
oil return 3
PL
Low-
voltage protection of compressor’s
drive DC bus bar
bb
Malfunction of temperature sensor of
oil return 4
PE
Phase-lacking of inverter compressor
bd
Malfunction of air inlet temperature
sensor of subcooler
PF
Drive charging circuit malfunction of
compressor
bn
Malfunction of liquid inlet temperature
sensor of subcooler
PJ
Failure startup of inverter compressor
H0
Malfunction of driving board of fan
(uniform)
PP
AC current protection of inverter
compressor
Summary of Contents for GMV-Y36WL/A-T
Page 1: ...Photovoltaic Multi VRF for North America Capacity 36 kBtu h 60 kBtu h Rated Frequency 60 Hz...
Page 3: ...GREE Photovoltaic Multi VRF for North America 1 PRODUCT...
Page 15: ...GREE Photovoltaic Multi VRF for North America 13 CONTROL...
Page 18: ...GREE Photovoltaic Multi VRF for North America 16 2 Wired Controller 2 1 Control panel...
Page 19: ...GREE Photovoltaic Multi VRF for North America 17...
Page 20: ...GREE Photovoltaic Multi VRF for North America 18 Button Graphics...
Page 28: ...GREE Photovoltaic Multi VRF for North America 26 4 3 2 2 Appearance...
Page 34: ...GREE Photovoltaic Multi VRF for North America 32 Installation is in progress...
Page 37: ...GREE Photovoltaic Multi VRF for North America 35 Installation is in progress...
Page 39: ...GREE Photovoltaic Multi VRF for North America 37 Click Next...
Page 57: ...GREE Photovoltaic Multi VRF for North America 55...
Page 69: ...GREE Photovoltaic Multi VRF for North America 67 Switchover of Software Languages...
Page 70: ...GREE hotovoltaic Multi VRF for North America 68 INSTALLATION...
Page 102: ...GREE hotovoltaic Multi VRF for North America 100 MAINTENANCE...
Page 147: ...JF00303833...