background image

 

 

To Users 

Thank you for selecting Gree’s product. Please read this instruction manual carefully before 

installing and using the product, so as to master and correctly use the product. In order to guide 

you  to  correctly  install  and  use  our  product  and  achieve  expected  operating  effect,  we  hereby 

instruct as below: 

(1)  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 

have been given supervision or instruction concerning use of the appliance by a person 

responsibility for their safety. Children should be supervised to ensure that they do not 

play with the appliance. 

(2)  In  order  to  ensure  reliability  of  product,  the  product  may  consume  some  power  under 

stand-by  status  for  maintaining  normal  communication  of  system  and  preheating 

refrigerant and lubricant. If the product is not to be used for long, cut off the power supply; 

please energize and preheat the unit in advance before reusing it. 

(3)  Please properly select the model according to actual using environment, otherwise it may 

impact the using convenience. 

(4)  This  product has gone  through strict  inspection  and  operational  test  before  leaving  the 

factory. In order to avoid damage due to improper disassembly and inspection, which may 

impact the normal operation of unit, please do not disassemble the unit by yourself. You 

can contact with the special maintenance center of our company if necessary. 

(5)  For personal injury or property loss and damage caused by improper operation such as 

improper  installation  and  debugging,  unnecessary  maintenance,  violation  of  related 

national laws and rules and industrial standard, and violation of this instruction manual, 

etc., we will bear no liability. 

(6)  When the product is faulted and cannot be operated, please contact with our maintenance 

center as soon as possible by providing the following information. 

1) Contents  of  nameplate  of  product  (model,  cooling/heating  capacity,  product  No.,  ex-

factory date). 

2) Malfunction status (specify the situations before and after the error occurs). 

(7)  All  the  illustrations  and  information  in  the  instruction  manual  are  only  for  reference.  In 

order  to  make  the  product  better,  we  will  continuously  conduct  improvement  and 

innovation. We have the right to make necessary revision to the product from time to time 

due  to  the  reason  of  sales  or  production,  and  reserve  the  right  to  revise  the  contents 

without further notice. 

(8)  The final right to interpret for this instruction manual belongs to Gree Electric Appliances 

Inc. of Zhuhai. 

 

 

 

Summary of Contents for GMV ND50PHS/B-T

Page 1: ...r Unit Models GMV ND22PHS B T GMV ND25PHS B T GMV ND28PHS B T GMV ND32PHS B T GMV ND36PHS B T GMV ND40PHS B T GMV ND45PHS B T GMV ND50PHS B T GMV ND56PHS B T GMV ND63PHS B T GMV ND71PHS B T GMV ND80PH...

Page 2: ...operational test before leaving the factory In order to avoid damage due to improper disassembly and inspection which may impact the normal operation of unit please do not disassemble the unit by you...

Page 3: ...m Testing 9 4 4 Installation of Air Duct 13 4 5 Installation of Wired Controller 15 5 Wiring Work 16 5 1Connection of Wire and Patch Board Terminal 16 5 2Power Cord Connection 17 5 3 Connection of Com...

Page 4: ...pe water pipe lightning arrester or telephone line Please use specialized accessories or parts to carry out installation or water leakage electric shock fire hazard may resulted R410A refrigerant can...

Page 5: ...set too low Keep the difference between indoor temp and outdoor temp within 5 C If abnormal condition occurs e g unpleasant smell please turn off the unit at once and disconnect power supply Then con...

Page 6: ...Temp Rated Cooling 27 80 6 19 66 2 35 95 24 75 2 Rated Heating 20 68 0 15 59 0 7 44 6 6 42 8 3 Preparations for Installation Note Product graphics are only for reference Please refer to actual produc...

Page 7: ...therwise by himself 3 2 Location for Installation 1 The appliance shall not be installed in the laundry 2 The top holder must be strong enough to support unit s weight 3 Drain pipe can drain water out...

Page 8: ...the unit by yourself Please contact local dealer to arrange professional technicians for the installation Do not connect power until all installation work is finished 3 3 Requirements for Communicati...

Page 9: ...nit and Indoor Outdoor Unit Wire size mm2 AWG Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 1000m L 3280 5 6ft 2 0 75 2 AWG18 IEC 60227 5 1 If t...

Page 10: ...ed person in order to avoid a hazard 2 Install cut off device near the unit The minimum distance between each stage of cut off device should be 3mm The same for both indoor unit and outdoor unit 4 Ins...

Page 11: ...the indoor unit temporarily Assemble suspension bolt on the expansion bolt attach the hanger bracket to the suspension bolt Be sure to fix it securely by using a nut and washer from upper and lower s...

Page 12: ...fig 4 2 2 Tighten the flaring nut with torque wrench Fig 4 2 3 Use pipe bend when bending the pipe and the bending angle should not be too small 4 Wrap the connection pipe and joint with sponge and th...

Page 13: ...elines are used for several units the position of pipeline should be about 100mm lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1 4 3 2 Drainage Pipe In...

Page 14: ...l pipe in the same level please select the connection way as shown in following fig NO1 Connection of drainage pipe joints Fig4 3 7 NO2 Connection of downspout elbow Fig4 3 8 NO3 Inserting pipe connec...

Page 15: ...1 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check the draining through the transparent part of drain socke...

Page 16: ...ade board with iron frame The junction of air duct should be well sealed in order to prevent air leakage The design and construction of air duct should comply with national requirements The edge of ai...

Page 17: ...he back and the return air cover plate is at the bottom as shown in Fig 4 4 4 Fig 4 4 4 2 If the bottom return air is desired just change the place of the rectangular flange and the return air cover p...

Page 18: ...ir baffle by sponge if the fresh air duct is not be used 2 Install the round flange so that the fresh air duct can be connected as Fig 4 4 7 3 Sealing and heat preservation should be done for both the...

Page 19: ...The communication wires should be separated from power cord and connection wire between indoor unit and outdoor unit Adjust the static pressure via wired controller according to site circumstance 5 1C...

Page 20: ...c box lid 2 Let the power cord pass through the wiring through holes 3 Connect the power cord to terminal L N 4 Fix the power card with wiring clamp 5 3 Connection of Communication Wire between Indoor...

Page 21: ...ig 5 4 1 shows the installation of wired controller Fig 5 4 1 Fig 5 4 2 2 Fig 5 4 2 shows the installation of remote controller 3 Wired controller and receiving light board can be installed at the sam...

Page 22: ...d by the same wired controller When the indoor unit is controlled by two wired controllers the addresses of the two wired controllers should be different through address setting Address 1 is for main...

Page 23: ...lid table when cleaning the unit Do not clean the unit with hot water whose temperature is higher than 45 C to prevent fade or deformation Do not dry the filters by fire or it may catch fire or become...

Page 24: ...air may cause electric shock or fire so please contact an authorized service center for professional service The following checks prior to contact may save your time and money Phenomenon Troubleshooti...

Page 25: ......