background image

Multi Variable Air Conditioners Ducted Type Indoor Unit

 

2

 

 

Never start or stop the air 
conditioner by inserting or 
removing the power cord. 

 

Do not turn off the air 
conditioner until it runs for at 
least 5 minutes. Otherwise, 
oil-return of the compressor 
will be affected. 

 

Children are not allowed to 
operate the air conditioner. 

 

Do not operate the air 
conditioner with wet hands. 

 

Please turn the unit off and 
unplug your air conditioner 
before cleaning. Otherwise, it 
may cause electric shock or 
personal injury. 
 

 

Do not spray water on the 
air conditioner or it will 
cause malfunction or electric 
shock. 

 

Do not expose the air 
conditioner directly to water or 
place it in a damp or corrosive 
environment. 

 

Connect power supply 8 
hours before operation. Do 
not disconnect power if you 
want to stop the unit in a 
short period of time, e.g. in 
one night. (This is for 
protecting the compressor.) 

 

Volatile liquid like thinner or 
gasoline will damage the 
appearance of air conditioner. 
(Please use soft dry cloth and 
wet cloth with mild detergent to 
clean the outer case of air 
conditioner.) 

 

During Cooling mode, indoor 
temperature should not be 
set too low. Keep the 
difference between indoor 
temp and outdoor temp 
within 5°C. 

 

If abnormal condition occurs 
(e.g. unpleasant smell), please 
turn off the unit at once and 
disconnect power supply. Then 
contact GREE service center. If 
the air conditioner continues to 
operate despite of abnormal 
condition, the unit may be 
damaged and it may cause 
electric shock or fire hazard.) 

 

Do not repair the air 
conditioner by yourself. 
Improper repair will cause 
electric shock or fire hazard. 
Please contact GREE 
service center and have it 
repaired by professional 
technicians. 

Any  personal  injury  or  property  loss  caused  by  improper  installation,  improper  debug, 

unnecessary repair or not following the instructions of this manual should not be the responsibility 

of Gree Electric Appliances, Inc. of Zhuhai. 

 

Correct Disposal of this product 

This marking indicates that this product should not be disposed with other 

household  wastes  throughout  the  EU.  To  prevent  possible  harm  to  the 

environment  or  human  health  from  uncontrolled  waste  disposal,  recycle  it 

responsibly to promote the sustainable reuse of material resources. To return 

your used device, please use the return and collection systems or contact the 

retailer  where  the  product  was  purchased.  They  can  take  this  product  for 

environmental safe recycling. 

R410A (R32/125:50/50):2087.5 

 

Summary of Contents for GMV ND50PHS/B-T

Page 1: ...r Unit Models GMV ND22PHS B T GMV ND25PHS B T GMV ND28PHS B T GMV ND32PHS B T GMV ND36PHS B T GMV ND40PHS B T GMV ND45PHS B T GMV ND50PHS B T GMV ND56PHS B T GMV ND63PHS B T GMV ND71PHS B T GMV ND80PH...

Page 2: ...operational test before leaving the factory In order to avoid damage due to improper disassembly and inspection which may impact the normal operation of unit please do not disassemble the unit by you...

Page 3: ...m Testing 9 4 4 Installation of Air Duct 13 4 5 Installation of Wired Controller 15 5 Wiring Work 16 5 1Connection of Wire and Patch Board Terminal 16 5 2Power Cord Connection 17 5 3 Connection of Com...

Page 4: ...pe water pipe lightning arrester or telephone line Please use specialized accessories or parts to carry out installation or water leakage electric shock fire hazard may resulted R410A refrigerant can...

Page 5: ...set too low Keep the difference between indoor temp and outdoor temp within 5 C If abnormal condition occurs e g unpleasant smell please turn off the unit at once and disconnect power supply Then con...

Page 6: ...Temp Rated Cooling 27 80 6 19 66 2 35 95 24 75 2 Rated Heating 20 68 0 15 59 0 7 44 6 6 42 8 3 Preparations for Installation Note Product graphics are only for reference Please refer to actual produc...

Page 7: ...therwise by himself 3 2 Location for Installation 1 The appliance shall not be installed in the laundry 2 The top holder must be strong enough to support unit s weight 3 Drain pipe can drain water out...

Page 8: ...the unit by yourself Please contact local dealer to arrange professional technicians for the installation Do not connect power until all installation work is finished 3 3 Requirements for Communicati...

Page 9: ...nit and Indoor Outdoor Unit Wire size mm2 AWG Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 1000m L 3280 5 6ft 2 0 75 2 AWG18 IEC 60227 5 1 If t...

Page 10: ...ed person in order to avoid a hazard 2 Install cut off device near the unit The minimum distance between each stage of cut off device should be 3mm The same for both indoor unit and outdoor unit 4 Ins...

Page 11: ...the indoor unit temporarily Assemble suspension bolt on the expansion bolt attach the hanger bracket to the suspension bolt Be sure to fix it securely by using a nut and washer from upper and lower s...

Page 12: ...fig 4 2 2 Tighten the flaring nut with torque wrench Fig 4 2 3 Use pipe bend when bending the pipe and the bending angle should not be too small 4 Wrap the connection pipe and joint with sponge and th...

Page 13: ...elines are used for several units the position of pipeline should be about 100mm lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1 4 3 2 Drainage Pipe In...

Page 14: ...l pipe in the same level please select the connection way as shown in following fig NO1 Connection of drainage pipe joints Fig4 3 7 NO2 Connection of downspout elbow Fig4 3 8 NO3 Inserting pipe connec...

Page 15: ...1 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check the draining through the transparent part of drain socke...

Page 16: ...ade board with iron frame The junction of air duct should be well sealed in order to prevent air leakage The design and construction of air duct should comply with national requirements The edge of ai...

Page 17: ...he back and the return air cover plate is at the bottom as shown in Fig 4 4 4 Fig 4 4 4 2 If the bottom return air is desired just change the place of the rectangular flange and the return air cover p...

Page 18: ...ir baffle by sponge if the fresh air duct is not be used 2 Install the round flange so that the fresh air duct can be connected as Fig 4 4 7 3 Sealing and heat preservation should be done for both the...

Page 19: ...The communication wires should be separated from power cord and connection wire between indoor unit and outdoor unit Adjust the static pressure via wired controller according to site circumstance 5 1C...

Page 20: ...c box lid 2 Let the power cord pass through the wiring through holes 3 Connect the power cord to terminal L N 4 Fix the power card with wiring clamp 5 3 Connection of Communication Wire between Indoor...

Page 21: ...ig 5 4 1 shows the installation of wired controller Fig 5 4 1 Fig 5 4 2 2 Fig 5 4 2 shows the installation of remote controller 3 Wired controller and receiving light board can be installed at the sam...

Page 22: ...d by the same wired controller When the indoor unit is controlled by two wired controllers the addresses of the two wired controllers should be different through address setting Address 1 is for main...

Page 23: ...lid table when cleaning the unit Do not clean the unit with hot water whose temperature is higher than 45 C to prevent fade or deformation Do not dry the filters by fire or it may catch fire or become...

Page 24: ...air may cause electric shock or fire so please contact an authorized service center for professional service The following checks prior to contact may save your time and money Phenomenon Troubleshooti...

Page 25: ......

Reviews: