Clean and maintenance
1.Pull out the drainage pipe
Note: Do not twist off
the silver screws.
Right drainage
pipe
Blade node
Lock status
Unlock status
Fig.1
Fig.2
drainage pipe
Bottom case and parts clean
Press the beige locking spring at both
ends of white drainage pipe simulta-
neously, and then pull the drainage
pipe backwards.
2.Remove the guard net
Caution: There may be residual water drop
in the drainage pipe. Please ensure drainage
pipe outlet face upwards when then
drainage pipe is removed.
Press guard net spring fastener at both sides
with both hands simultaneously and pull it
upwards,and then remove the guard
net.
3.Remove blade
①
Rotate the blade slightly and the find the silver
screw at the right side of the blade. Use the
screwdriver to loose the silver screw for
2-3 circles slowly in an anti-clockwise direction.
(as shown in fig.1)
②
Until the blade can slide to the left side to
unlock status (as shown in fig.2).
Caution
If the screw is removed carelessly when disassembling
the blade, put the blade sub-assy on the ground flatly,
rotate the screw into the axle sleeve of blade (2-3 circles
clockwise), fix the blade sub-assy at the indoor unit and
then fix the screw at the motor shaft. Tighten the screws
as shown in the right figure (2-3 circles clockwise).
13