 Precautions

 

If electric shock suddenly happens, turn off 

the unit. If the unit is not to be used for a long 
period, cut off the main power supply. 

      

 

Check electrical system (voltage and 

frequency). Use proper power supply indicated 
on the unit to operate the air conditioner and 

only fuses wuth specified capacity, Do not use 

pieces of wire instead of fuse.

     

 

Do not insert objects into the air inlet or outlet 

when the air conditioner is running as it may 

cause damage or personal injury. Also pay 

special attention when children are around.

   

 

Do not place any obstacles around the 

indoor and outdoor unit to avoid of inefficient 
performance or malfunction.

 

   

    

   

 

Never expose infants, aged persons or 

patients directly to the air flow.

  

 

Do not locate a heater or any other heat 

source close to the unit. The heat may deform 
plastic parts.

  

     

Summary of Contents for FP-102WM-D

Page 1: ...D FP 102WM K BMS FP 34ZD K FP 51ZD K FP 68ZD K FP 85ZD K FP 102ZD K FP 136ZD K FP 170ZD K FP 204ZD K FP 136WM K BMS Thank you for choosing commercial air conditioners Please read this Owner s Manual c...

Page 2: ...l DISPOSAL This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled w...

Page 3: ...g 4 5 Installation 4 5 1 Dimension 4 5 2 Selection of Installation location 5 5 3 There are two types of installation 5 5 4 Electrical wiring 7 6 Drain Piping Work 8 7 Motorized valve 9 7 1 Installati...

Page 4: ...or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 2 Children sh...

Page 5: ...le to blow all over the room Clean the air filter every week for higher efficiency by professional Close the window and door while operating the unit for saving energy Cover windows with a blind or a...

Page 6: ...ecified capacity Do not use pieces of wire instead of fuse Do not insert objects into the air inlet or outlet when the air conditioner is running as it may cause damage or personal injury Also pay spe...

Page 7: ...me coming out of the unit while running Hot air in the room mixes with cool air This causes smoke fume Inoperative remote control Loosened or disconnected wire between the unit and the display Check i...

Page 8: ...more 60cm or more Fig 1 Fig 2 5 3 There are two types of installation Ceiling type Floor type Fig 3 Each type is similar to the other as follows 1 Determine the mounting position on ceiling or wall 2...

Page 9: ...of the drain pipe slightly inclines to improve drainage Adjust the height by turning the nut with a spanner Insert the spanner from the hanger bracket opening Refer to Fig 8 Hanging installation It i...

Page 10: ...sulated power cable used at 40 and resistible to 90 see GB T 16895 15 If the working condition changes they should be modified according to the related national standard Rubber bush Wiring clamp Power...

Page 11: ...tely into the drain socket Tighten the clamp within the range of gray tape until the screw head is less than 4 mm from the hose Refer to Fig 12 13 5 Wrap the attached sealing pad OD over the clamp and...

Page 12: ...uaranteed Flare nut Wiring interface Water outlet tube Torque wrench Thread fasten Spanner Valve Tape Water tube joint Fig 16 2 Both the tube joint and the motorized valve are G3 4 threaded Prior to t...

Page 13: ...ould allow the condensate water to enter or damage the valve core and even form a short circuit which wouldresult in a fire hazard as Fig 20 Fig 20 The right way is placing the valve core in the prope...

Page 14: ...function or damage the part Has the inlet and outlet been covered It may cause insufficient cooling or heating capacity 10 Test Operation wireless remoter controller 10 1 Before test operation 1 Do no...