08/01/2018
500-641M
TSF1080, TSF1090, TSF1280 & TSF1290
Operations
46
Main Fill Using Supply Pump
If relying on gravity, make sure the supply tank is higher than
the sprayer tank.
If relying on an external pump, make sure there is sufficient
pressure at the tank inlet (nominally, at least 10 psi).
Failure to do so can cause back-flow from the sprayer tank
causing sickness, serious injury or death from water
contamination.
If the supply pump at the water source is a positive
displacement type, do not start it until after opening the ball
valve
at the inlet.
1.
Close the ball valve
at the main tank inlet.
2.
Set panel valve
to MAIN TANK.
3.
Set panel valve
to SPRAY.
4.
Connect the supply hose to the quick-fill Cam-Lock
coupler .
5.
If using gravity or a pump that is
not
positive
displacement, turn on the water source.
6.
Open the quick-fill ball valve
.
7.
If using a positive displacement pump, turn it on.
8.
When the tank is filled to the required level:
•
If using gravity or a pump that is not positive
displacement, close the inlet ball valve
, then
shut off the water source.
•
If using a positive displacement pump, shut off
the pump, and then close the inlet ball valve
.
Figure 34
Main Tank Fill with Supply Pump
22673
3
2
1
2
3