Great Plains | 166-486M | 2020/10/08
106
Spartan
II
607
Troubleshooting
Planting too little - all
rows (cont’d)
Actual field size is different.
Verify field size.
Excessive pass gaps.
Irregular shaped field.
Adjust marker (page 67).
Build-up of treatment or debris in seed
meter.
Clean out seed meter (page 75).
Plugged opener seed tube.
Lift drill, expose bottom of seed tube, and
clean out.
Meter sprocket damaged
Replace worn or damaged stars on
metering shaft
Planting too much - all
rows
Incorrect seed rate, meter flutes, or rate
range setting.
Check material rate information beginning
on page 44.
Seed size and weight or fertilizer density
and granularity change
Calibrate. Adjust rate to compensate.
Seed or fertilizer density and granularity
may vary from season to season, batch to
batch, and between different suppliers.
Calibrate again if materials might have
changed since last calibration (page 50).
Actual field size is different.
Verify field size.
Excessive pass overlap.
Irregular shaped field.
Adjust marker (page 67).
Planting too much -
some rows
Dividers damaged or missing in towers.
Disassemble tower turrets. Replace
damaged or worn parts.
Worn/damaged flute stars in meter.
Inspect empty meter from above. Remove
meter from below and repair.
Uneven seed depth
Excessive field speed
Slow down. Check monitor for correct
maximum field speed.
Implement not level
Check leveling instructions (page 57).
Planting conditions too wet
Wait until drier weather.
Uneven seed spacing
Excessive field speed.
Reduce field speed.
Drill not level
Check level (page 57) and weight transfer
(page 58).
Planting conditions too wet.
Wait until drier weather.
Seed
-
Lok™ building up with dirt.
Lock up Seed
-
Lok™ (page 65).
Damaged or missing seed flaps.
Replace seed flaps.
Partially plugged opener seed tube.
Expose bottom of seed tube and clean out.
Opener disks not
turning free
Opener plugged with dirt.
Clean opener.
Planting conditions too wet.
Wait until drier weather.
Seed
-
Lok™ is plugging opener.
Lock up Seed
-
Lok™ (page 65).
Failed disk bearings.
Replace disk bearings.
Bent or twisted opener frame.
Replace opener frame.
Partially plugged opener seed tube.
Lift up drill, expose bottom of seed tube, and
clean out.
Problem
Causes
Solutions
Summary of Contents for SPARTAN II
Page 12: ...Great Plains 166 486M 2020 10 08 6 SpartanII 607 Table of Contents Index Safety Information ...
Page 125: ...Great Plains 166 486M 2020 10 08 118 SpartanII 607 Table of Contents Index ...
Page 127: ...Great Plains 166 486M 10 08 2020 120 SpartanII 607 Table of Contents Index Warranty ...
Page 130: ...Table of Contents Index ...
Page 131: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 ...