Great Plains
| 166-207M | 02/26/2019
152
NTA907HD and NTA3007HD
Appendix A - Reference Information
Monitor Setup Data
Seed monitor setup is normally performed using the
Quick Start Guide (QSG, part number 110011516). If the
QSG is not available, the table at right, plus the
Specifications and Capacities data starting on page 143,
provide the required and key factory default settings.
Notes:
a
Required Value:
Do not change.
b
Factory Default:
An approximate initial value. Refine with material data and/
or calibration.
c
Type:
Change to “GRAN...CONTROL” if optional variable rate
seeding is installed.
Note
NTA907HD NTA3007HD
Row Setup
Model: NTA..-3610
a
9 sensors/WSMB
Model: NTA..-4875
a
12 sensors/WSMB
Model: NTA..-6006
a
15 sensors/WSMB
Ground Speed
Source
a
Digital Frequency
Constant
b
38416
46837
Alarm Delay (generally)
b
5 sec
Accessory Setup
Hopper Level Logic
a
ACTIVE LO
Front Hopper is no.
a
1
# of RPM sensors
a
1
Fan RPM Constant
a
3 pulses/rev
RPM filter
a
50 %
# of Pressure Sensors
a
2
High Alarm
b
8.6 kpa
20 oz/in3
Low Alarm
b
1.7 kpa
4 oz/in3
Pressure Filter
a
50
Material Setup
Type (for seeding)
c
GRAN SEED MONITOR
Type (for fertilizer)
c
GRAN FERT MONITOR
Total # of Towers
a
4
Material Defaults
Seed
b
0.77 kg/l
60 lbs/bu
Fertilizer
b
0.96 kg/l
60 lbs/ft3
Calibration Constants
Seeding
b
3031
85831
Fertilizer
b
2931
82996
Channel Setup
Input Filter
a
50%
Sensor Constant
a
360 pulses/rev
Gear Ratio
a
1