Place the pin in the pull-bar transport lock. This must
always be used when transporting the drill in the
folded position.
Lifting the Drill
The lift cylinders may after a period of time get out of
time or phase. The effects of this can be seen when one
side of the drill is running too low or too high because its
lift cylinder is either overextended or not retracted
compared to the other lift cylinders.
To rephase the cylinders, raise the drill completely up
and hold the tractor hydraulic lever on for a few seconds
to give the cylinders time to rephase. This should be
done each time the drill is raised out of the ground.
Momentarily reversing the hydraulic lever immediately
after rephasing to allow the cylinders to retract about
1
/
2
inch will help in maintaining a level drill.
NOTE:
Understand that having the cylinders become
gradually out of time is different than having air
trapped in the system from improper bleeding. Each
condition is corrected differently.