Discharge mode selection in cycle mode
Charge mode selection in cycle mode
The start delay time can be set at values betwee 1-150
minutes.
After the preset delay time has completed, the charger initi-
ates the cycle charge/discharge.
Start delay time
The number of operating cycles is shown
Cycle operating screen
The operating indicator blinks at the top
Tap the graph to display the operating data
The charge mode and the start delay time parameters are programmed.
Tap the box to activate (blue). Tap the DEC/INC button to select the
desired mode. Discharge modes are explained below
After counting down, the charger initiates the discharge process.
Tapping the Enter button will cause the charger to
immediately initiate the charging process.
After connecting the balance board, the charger can check
the number of cells. If the confirmed number of cells is not
correct, tap the ESC button to return to the previous page.
Re-check the parameters. With the correct number of cells,
the next page will be accessed automatically.
To initiate the process without a balance board, the cell can
be activated and the number of cells programmed into the
cell. Tapping the Enter button will cause the charg-
er to immediately initiate the charging process.
This page (left) shows the battery check process after a con-
nection to the balancer has been established. The next page
is accessed
automatically. Tapping the Enter button will cause
the charger to immediately initiate the charging
process.
Tap the part in the red circle (left) to display the set current
window. The charge/discharge current parameters used dur-
ing the operations can then be entered. Tap the X button to
close the set current window. These parameters are used by
the charger during the operation and are not stored in the
memory.
This page (left) shows the cycle process with the parameters and graph.
Both the voltage and current values will increase to the preset parameters.
The preset current may be limited by the charge/discharge capacity and
ithe nput voltage setup. The max charging process operates at 400W with
a max discharging process at 60W.
Cycle operation mode per battery type
Cycle charge discharge mode of the POLARON EX Charger
LiPo, LiIon, LiFe, Pb
NiCd, NiMH
CC-CV : Normal charge mode
NORMAL : Normal discharge mode
LINEAR : The preset current is maintained throughout the
discharge process.
AUTO : The charge will automatically adjust the
charge/discharge conditions
NORMAL : Normal charge/discharge
LINEAR : The preset current is maintained throughout the
charge/discharge process.
Battery Cell Checking
Number of cells checking