Eng
lish
INNOVATION & TECHNOLOGIE
50
51
Other port is in use!
Motor stop
◄ The motor was stopped because the other output is in use.
Please check your parameters.
Calibration data
or internal circuit
might have been
damaged.
Calibration
◄ Errors in calibration or in the circuits of the device. If the error
message appears repeatedly, please contact the service.
Sync order failed.
Error occurred in the
counterpart channel!
Sync. Command
◄ The cell count in the menu charge / discharge and Sync Mode
menu does not match with the detected number of cells on
Channel 1 and Channel 2.
Troubleshooting
Problem
Possible causes
When connecting the
charger the display
remains dark
• Check that the external power supply meets the requirements of the
charger and that all cables are properly connected. If the problem per-
sists, contact the Service.
The charger does not
recognize the battery
• Check whether the battery is properly connected to the charge port
and the balancer.
• Check whether a cell of the battery is defective.
The battery voltage is
too low after charge
• Check whether the charge settings are correct.
• Check the set delta peak value of NiCd / NiMH batteries.
• Check the connecting cable of the battery.
Discharge mode is not
retrieved
• Check if the selected cell voltage matches the battery features.
• Check whether a cell of the battery is defective.
Battery is not fully
charged after the maxi-
mum charging time
• Charge the battery pack. Run a full cycle charge process by improving
the capacity (battery has been stored for too long or is consumed).
• Check whether in the charge cycle, the minimum discharge voltage
correctly is set.