Eng
lish
INNOVATION & TECHNOLOGIE
38
39
PM
02:19:54
CH1
CH2
MOTOR
Time
Voltage
0s
5m
7.20V
0
m
0
s
0.98
V
1
2
3
4
BREAK-IN
1 After tap the minutes and / or seconds field to select the period of break-in
process (Setting range: 0 m / s 0 ... 300 m / 59 s, default is 5 m / s 0)
2 After tap the voltage field line to select the operating voltage value supplied
by the battery charger for the break-in process (setting range: 0.1 V ... 24 V
in 0.1 V increments, default value: 7.2 V)
3 Displays the period since the start of the break-in operation
4 Displays the actual output voltage or charge voltage of the buffer capacitor
Pressing the STOP button at the bottom of the display stops the operation.
Display “Program“
Connect your brushed motor directly to output CH1 or CH2 and select the appropriate channel
from the display.
After opening the submenu “BREAK-IN“ pull down in the lines ”time“ and “voltage“ you may deem
suitable values.
Parameter
Short description
Cycle
1 ... 10 cycles adjustable (default 5)
1st … 4th
first to fourth sub-cycle
Volt
0.1 ... 12 V output voltage adjustable in 0.1 V increments
On
from 1 ... 37 seconds motor run time
Off
from 0 ... 37 seconds pause
Pressing the ENTER button under the display starts the intake of such pre-pro-
grammed cycle of your brushed motor, the motor start-up is always soft.
Pressing the STOP button at the bottom of the display stops the operation.
Display “Motor test“
In this screen is shown the average current and peak current consumption of
the checked brushed motor directly connected to the CH1 or CH2 outputs.
Parameter
Short description
Voltage
4.8 or 7.2 volts selectable (default 7.2 V)
1st … 6th
first to sixth sub-cycle
0.0Aa
medium current consumption in each sub-cycle (amps
average)
0.0Ap
maximum current consumption in each sub-cycle (amps
peak)
It will go through 6 passages, wherein the voltage gradually increases from
passage to passage to maximum supply voltage - up to the value preselected
in the “voltage” line.
The duration of each sub-cycle is 5 seconds and the waiting time between the
sub-cycles is 3 seconds.
Pressing the ENTER button under the display starts the test of your brushed motor, the motor
start-up is always soft.
Pressing the STOP button at the bottom of the display stops the operation.
PM
02:23:54
CH1
CH2
MOTOR
CYCLE
Volt Run Delay
5
PROGRAM
1st
2nd
3rd
4th
1.2V
4.8V
7.2V
6.0V
6s
6s
6s
6s
5s
5s
5s
5s
PM
02:54:23
CH1
CH2
MOTOR
Test Voltage
MOTOR TEST
1st
2nd
3rd
4th
0.0
Aa
0.0
Aa
0.0
Aa
0.0
Aa
0.0
Ap
0.0
Ap
0.0
Ap
0.0
Ap
5th
6th
0.0
Ap
0.0
Ap
0.0
Aa
0.0
Aa
7.2V
Summary of Contents for POLARON EX-1400