Eng
lish
INNOVATION & TECHNOLOGIE
24
25
Start the discharge
PM
01:23:54
DISCHG
Charge Mode
Discharge mode
CH1
CH2
00 NiCd Auto Mode
NONE
AUTO
Balancer port is
not connected...
00:00:00
... One-tap the ENTER button on the bottom right of the display brings on the
second display page of the „DISCHARGE“ menu.
In parallel, the battery charger balancer checks the active channel CH1 or CH2
charge and compares the number of cells of the connected battery with the
default settings, then, if necessary, appropriate messages are shown on the
display.
PM
01:23:59
DISCHG
Charge Mode
Discharge Mode
CH1
CH2
NONE
AUTO
00:00:00
Start Delay Time
00 NiCd Auto Mode
5
Then you have about five seconds to possibly set a start delay.
Discharge modes
• AUTO
NiCd / NiMH / Pb:
Automatic discharge mode, which checks the number of cells and determi-
nes the discharge itself.
By default preset turn-off: NiCd = 0.9 V / cell, NiMH = 0.8 V / cell, Pb = 1.8 V / cell.
The choice of a charge mode is the NOT possible.
• LINEAR
NiCd / NiMH / LiIo / LiPo / LiFe / Pb:
The battery is then discharged under the maximum
discharge capacity of the polaron EX-1400 of 60 W with the given discharge current, then the
charger discharges the battery without any interruption for 3 minutes after the start and determi-
nes internal resistance.
The choice of a charge mode is the NOT possible.
• NORMAL
NiCd / NiMH / LiIo / LiPo / LiFe / Pb:
The battery is then discharged under the maximum
discharge capacity of the polaron EX-1400 of 60 W with the given discharge current.
The choice of a charge mode is the NOT possible.
• LINK
Note:
This discharge mode is only available in the menu to CH1.
LiIo / LiPo / LiFe:
batteries with the same capacity and the same number of cells can be
discharged at two charge ports with just a simultaneous setting.
In different cell number, an error message is displayed and the discharge operation aborts.
The choice of a charge mode is the NOT possible.
Summary of Contents for POLARON EX-1400
Page 52: ...English 52 ...