background image

33302  RF Module M-G2 HoTT SD mx-22/24/mc-24

GRAUPNER GmbH & Co. KG – Postfach 1242 – 73230 Kirchheim/Teck – www.graupner.de

CONTENT:

1.     Introduction..............................................................................................................01
2.     Preparing the systems.............................................................................................01
3.     Installation mx-series...............................................................................................02
4. Installation 

mc-series...............................................................................................03

5. General 

Note..............................................................................................................05

5.1.  Transmitter Display (TX Display)................................................................................05
5.2. Receiver 

Display.........................................................................................................07

5.2.1. Receiver Data View (RX DATAVIEW).........................................................................07
5.2.2. Servo Data (RX SERVO)............................................................................................08
5.2.3. Failsafe Setup (RX FAILSAFE)..................................................................................09
5.2.4. Mixer Setup (RX FREE MIXER - WING MIXER)......................................................11
5.2.5. Expo functions (RX CURVE)......................................................................................12
5.2.6. Servo test (RX SERVOTEST)....................................................................................13

6.  

Functions.....................................................................................................15

6.1.  Binding.............................................................................................................15

6.1.1.Binding multiple receivers in one model...................................................................15
6.2. Range 

checking..........................................................................................................15

6.3.  Fail Safe Function .......................................................................................................16
6.4. Country setting...........................................................................................................17
6.5.  Low voltage warning..................................................................................................17
6.6. Range warning...........................................................................................................17
6.7. DATA socket...............................................................................................................17
6.8. Data storage...............................................................................................................18
6.9. Earphone 

socket.........................................................................................................18

7.  

Firmware  Updates....................................................................................................19

7.1.   Update  process..........................................................................................................19

8.  

Warranty....................................................................................................23

Summary of Contents for HOTT M-G2

Page 1: ...ata View RX DATAVIEW 07 5 2 2 Servo Data RX SERVO 08 5 2 3 Failsafe Setup RX FAILSAFE 09 5 2 4 Mixer Setup RX FREE MIXER WING MIXER 11 5 2 5 Expo functions RX CURVE 12 5 2 6 Servo test RX SERVOTEST 13...

Page 2: ...PREPARING THE SYSTEM mc series First remove your previous RF module For details of this procedure please refer to the appropriate chapter in the operating instructions supplied with your radio control...

Page 3: ...he connector contacts are correctly positioned otherwise they could be damaged when you plug the module in do not use force The aerial connector can now be in serted in the socket on the module using...

Page 4: ...MC SERIES 1 1 2 2 1 1 03 Manual Module M G2 33302 Fig 5 Fig 6 Fig 6 Fig 7 Fig 7 Fig 8 Fig 8 Fig 9 Fig 9 Fig 10 Fig 10 Fig 11 Fig 11 Fig 12 Fig 12 Use the white washer securing the telescopic antenna 1...

Page 5: ...cover engage the two lugs in the left hand side of the module case then fit the two screws to secure it Check that it is correctly located Fig 13 5 We recommend that you cut openings for the BIND RAN...

Page 6: ...must be used for programming if you are using any of the following transmitters mx 22 Order No 4801 4802 mc 19 Order No 4821 mc 22 Order No 4818 and mc 18 Order No 4835 The following instructions desc...

Page 7: ...autic module is used set MULTIC to 00 Note The cycle time PERIOD must be set to 20 msec the channel sequence CH OUTPUT TYPE to SAME so that the function is activated Parameters which have different op...

Page 8: ...check the receiver installation and the power supply systems in your model and radio control system When operating your model this value should not fall below 90 dBm If it does you should reduce the d...

Page 9: ...m operating voltage L R VOLT displays the lowest receiver operating voltage since the last time the receiver was switched on If this voltage differs significantly from the actual operating voltage R V...

Page 10: ...vailable separately for each direction Cycle time PERIOD at this point it is possible to define the speed of the servos response to move ments of the transmitter controls This adjustment applies to al...

Page 11: ...This can be exploited for example to prevent the operation of a retractable undercarriage or similar function if the receiver is switched on accidentally However during normal model operations the cor...

Page 12: ...R appears on the screen Display Description Setup MODE Mode 1 2 3 MASTER CH Master channel 0 1 8 SLAVE CH Slave channel 0 1 8 SLAVE TRAVEL Limit Servo travel negative 0 150 SLAVE TRAVEL Limit Servo tr...

Page 13: ...the neutral position but its response reverts to a more linear curve with increasing control surface travel B linear setting the servo s response to stick movements is linear C EXPO setting i e the se...

Page 14: ...ashes at top right in all the Smartbox s receiver displays at the same time the parameter R VOLT is displayed in inverse form in the receiver data display RX DATAVIEW Receiver temperature monitor ALAR...

Page 15: ...iver must be programmed as SUMI Note that the signal only ever moves towards SUMI The receiver outputs are addressed in sequence at a frame rate of 20 ms 30 ms with the GR 24 re ceiver Order No 33512...

Page 16: ...must be connected to this unit as only the Master receiver transmits sensor data using the downlink channel The second and all further receivers operate in parallel with the Master receiver but in Sl...

Page 17: ...repeated brief presses of the BIND RANGE button on the trans mitter module cycle through the fail safe modes fail safe on off hold mode or standard Locate the BIND RANGE button on the back of the modu...

Page 18: ...reen LED flashes continuously Once you have selected the Country setting save it in the transmitter by holding the BIND RANGE button pressed in for about three seconds When you release the button the...

Page 19: ...er before the beep display OFF appears no log data is saved By default always the transmitter and receiver data with integrated telemetry or transmitter only wit hout integrated telemetry are recorded...

Page 20: ...to the module M G2 7 1 Update procedure Ensure that the adapter lead is configured as shown in the illustrations and is connected correctly to the transmitter or receiver Start the Graupner Firmware U...

Page 21: ...on the receiver also light up when the process is complete the green LED goes out and the red LED starts flashing Switch your transmitter receiver off and disconnect the ad apter lead Caution after c...

Page 22: ...isierte Normen Harmonised standards applied EN 60950 2006 EN 301 489 1 V1 7 1 EN 301 489 3 V1 4 1 EN 300 328 V1 7 1 Health and safety requirements pursuant to 3 1 1 Article 3 1 a Protection requiremen...

Page 23: ...e recycled and re used You can make an important contribution to the protection of our common environment by re using the product recycling the basic materials or recycling redundant equipment in othe...

Page 24: ...soci t Graupner GmbH Co KG Henriettenstra e 94 96 73230 Kirchheim Teck Allemagne accorde sur ce produit une garantie de 24 mois partir de la date d achat La garantie prend effet uniquement sur les vic...

Page 25: ...____________________________________________________ ____________________________________________________________ ____________________________________________________________ _________________________...

Page 26: ...________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________...

Page 27: ...________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________...

Page 28: ...t supplier We accept no liability for printing errors Sous r serve de modifications et de possibilit de livraison Livraison uniquement au travers de maga sins sp cialis s en mod lisme Nous pourrons vo...

Reviews: