13 / 16
3975_MP_V1
Connection example: all-round light bars
Rotating light: black
Parking light: white
Plus pole: red
Demo mode
The Kingbus central module can play a demonstration of the light
controls by briefly tapping the Prog button (less than a second). This
can be used for example to make the model more visible at exhibi-
tions. Remote control is not necessary for this mode! Press the Prog
button again briefly to stop the demo mode.
Connection diagram universal module front
Technical data
Operating voltage: 5 Volt via Kingbus
Connection cable: 150mm, Kingbus connector
Dimensions: 27 x 15 x 8mm
Note
The Uni-Mod is equipped with a spring-loaded terminal. The proce-
dure for connecting the cables is described below:
Insert the connection pin into the rectangular opening (notice-
able resistance must be overcome, terminal opens)
Insert the cable into the round hole until it stops
Carefully remove the pin
Check cable for tightness