Technical data

GR-12

Antenna

1 x wire 145 mm 

of which Antenna 30 mm

Operating voltage

(2.5) 3.6 ... 8.4 V

Frequency range

2400 ... 2483.5 MHz

Modulation

2.4 GHz FHSS

Number of controls

6

Current consump-

tion approx.

70 mAh

Temperature range

-15 … +70°C

Dimensions approx.

36 x 21 x 10 mm

Weight approx.

7 g

GR-16

Antenna

2x cable 145 mm,  

of which last 30 mm active

Operating voltage

(2.5) 3.6 ... 8.4 V

Frequency range

2400 ... 2483.5 MHz

Modulation

2.4 GHz FHSS

Number of controls

8

Current consump-

tion approx.

70 mAh

Temperature range

-15 … +70°C

Dimensions approx.

46 x 21 x 14 mm

Weight approx.

12 g

Summary of Contents for 33506

Page 1: ...EN No 33506 33508 33512 and 33516 6 8 12 and 16 channel 2 4 GHz HoTT receiver GR 12 GR 16 GR 24 and GR 32 HoTT Manual C o p y r i g h t G r a u p n e r S J G m b H ...

Page 2: ...2 24 33506_33508_33512_33516_T1V2sh ...

Page 3: ... receiver 9 For your safety by handling the batteries 9 Installation 10 Connections 10 Power supply 10 Binding 11 Receiver reset 12 Setting and display of the receiver settings 13 Special features of the GR 12 HoTT receiver 13 Special features of the GR 16 HoTT receiver 15 Special features of the GR 24 and GR 32 HoTT receiver 17 Firmware update 21 SIMPLIFIED DECLARATION OF CONFORMITY 22 Manufactur...

Page 4: ...s To maintain this condition and to ensure safe operation you must read and follow this user manual and all the safety notes before using the product and you have to respect those notes also for future use Note This manual is part of that product It contains important informa tion concerning operation and handling Keep these instructions for future reference and give it to third person in case you...

Page 5: ...ourself about the laws and regulations applicable at your respective starting point before starting the remote control operation Such conditions may differ from state to state but this must be followed in every case Note Read through this entire manual before you attempt to install or use the transmitter Target group The item is not a toy It is not suitable for children under 14 The installation a...

Page 6: ... controls 6 Current consump tion approx 70mAh Temperature range 15 70 C Dimensions approx 36 x 21 x 10 mm Weight approx 7 g GR 16 Antenna 2x cable 145 mm of which last 30 mm active Operating voltage 2 5 3 6 8 4 V Frequency range 2400 2483 5 MHz Modulation 2 4 GHz FHSS Number of controls 8 Current consump tion approx 70mAh Temperature range 15 70 C Dimensions approx 46 x 21 x 14 mm Weight approx 12...

Page 7: ...x 31 x 14 mm Weight approx 16 g GR 32 Antenna 2x cable 145 mm of which last 30 mm active Operating voltage 2 5 3 6 8 4 V Frequency range 2400 2483 5 MHz Modulation 2 4 GHz FHSS Number of controls 16 Current consump tion approx 140mAh Temperature range 15 70 C Dimensions approx 63 x 30 x 14 mm Weight approx 24 g Connection table Updates and telemetry SUMDIN CH OUTPUT TYPE Sum signal etc Optional vo...

Page 8: ... by a responsible person Operation and use of radio controlled models needs to be learnt If you have never driven such a model then start extra carefully and make sure to be familiar with the reactions of the model to the remote control commands Proceed responsibly First always perform a range and function test on the ground to do so hold your model tight before you use your model Repeat the test ...

Page 9: ...construction and or modification of the product is prohibited Note During transport protect the model and the transmitter from dam ages For your safety by handling the batteries CAUTION Protect the batteries from dust dirt moisture heat and vibra tions Only use in dry locations Do not use any damaged battery Batteries may not be heated burned short circuited If handled improperly there is a danger...

Page 10: ...mbered The polarity of the plug in system cannot be reversed Do not apply force Note For the GR 12 HoTT receiver insert the connectors with the brown or black cable upwards Power supply For the battery connection are designated the ports provided with an additional B In principle however you can connect a battery to any free socket By V or Y cable also with any remote control com ponent We recomme...

Page 11: ...24 HoTT or GR 32 HoTT receiver blinks in red with a slow rhythm 3 Push and hold for about three seconds the SET button on the receiver ശ ശ The LED of the GR 12 HoTT receiver remains still dark ശ ശ After this time has elapsed the LED of a GR 16 HoTT GR 24 HoTT or GR 32 HoTT flashes red and green simultaneously for a further approx three seconds During this time the related receiver is in bind mode ...

Page 12: ... out on an already connected receiver and the associated model memory is active in the switched on transmitter then the green LED of a receiver GR 12 HoTT GR 16 HoTT GR 24 HoTT or GR 32 HoTT should again be con stantly lit and thus signal a correct connection to the transmitter Otherwise the process has to be repeated Notes Through a RESET ALL of the settings in the receiver are brought to the fac...

Page 13: ... SERVO TEST page of the telemetry menu the output 6 can be used for different scopes Carry out the changeover as described in the instructions for the transmitter or the SMART BOX By setting ONCE or SAME to connect a servo ESC Gyro etc ശ ശ ONCE The servo connections of the receiver are actuated sequen tially The receiver power supply is less stressed ശ ശ SAME The servo connections of the receiver ...

Page 14: ...including their digital switches ശ ശ SBUS Digital sum signal in SBUS format BATT V After switching as described before a DC voltage off max 25 5 V can be displayed instead of the receiver voltage This way it is possible to monitor the main battery voltage without using exter nal sensors The ESCs S3082 and S3083 have this switch already included s 50 mm 100nF 2k7Ω 22kΩ max 25 5 V 100 mm Attention N...

Page 15: ... supply with an output voltage higher than 8 4 V directly to a connection port of the receiver The receiver and all connected devices would be immediately destroyed Connection 7 SERVO Input 7 is suitable for operating RC components SUMDIN Port 7 is suitable as input to a SUMD signal provided by receivers GR 16 GR 24 or GR 32 ശ ശ If a GR 16 GR 24 GR 32 receiver is set to SUMD as described below und...

Page 16: ...multaneous start up of up to four ser vos has a noticeably higher load on the receiver power sup ply SUMO SUMI SUMD SUMD3 or SBUS to connect a sum signal cable ശ ശ SUMO PPM modulated sum signal OUT of the control channel 04 to max 16 ശ ശ SUMI Sum signal IN in case of satellite receiver ശ ശ SUMD Digital sum signal of the control channel 04 to max 16 HD Hold the last servo position in case of Fail S...

Page 17: ... connection is created SUMD SUMDIN GR 16 HoTT and GR 24 HoTT CH8 CH7 GR 32 HoTT S CH7 Connection 8 GR 24 Connection S GR 32 CH OUTPUT TYPE Depending on the settings in the CH OUTPUT TYPE line of the RX SERVO TEST page of the telemetry menu the output 8 can be used for different scopes Carry out the changeover as described in the instructions for the transmitter or the SMART BOX By setting ONCE or ...

Page 18: ...ital sum signal of the control channel 04 to max 16 HD Hold the last servo position in case of Fail Safe FS Moving to the programmed positions in case of Fail Safe OF OFF switch off of the SUMD signal in case of Fail Safe ശ ശ SUMD3 Digital sum signal adapted to the transmitter mz 32 HoTT for the transmission of 32 control channels including their digital switches ശ ശ SBUS Digital sum signal in SBU...

Page 19: ...19 24 33506_33508_33512_33516_T1V2sh ...

Page 20: ...20 24 33506_33508_33512_33516_T1V2sh ...

Page 21: ...t be reversed Note the small chamfers on the sides Do not use force the plug should click into place easily For the GR 12 HoTT receiver plug the other end of the adapter cable into the 5 T position and for the GR 16 GR 24 and GR 32 HoTT receivers into the socket marked T The polarity of the plug in system cannot be reversed Do not apply force The plug should be fully inserted The update is carried...

Page 22: ... HoTT No 33508 GR 24 HoTT No 33512 and GR 32 HoTT No 33516 comply with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following Internet address www graupner de Manufacturer Graupner Co Ltd Post Code 14557 8th F 202 Dong Chunui Techno Park II 18 198 Street Bucheon ro Wonmi Gu Bucheon Shi Gyeonggi do South Korea ...

Page 23: ...conditions Graupner SJ GmbH Henriettenstrasse 96 73230 Kirchheim Teck grants from the date of purchase of this product for a period of 24 months The warranty applies only to the material or operational defects already existing when you purchased the item Damage due to misuse wear overloading incorrect accessories or improper han dling are excluded from the guarantee The legal rights and claims are...

Page 24: ......

Reviews: