BAV-0808
Rev. 0
10
5.5
Programming of restrictions
If the user enables the Restrictions option, the previously programmed restrictions will be fetched from
the on-board memory during power-up. Putting the panel in “Restrictions Programming mode” may
program new restrictions. This is done, starting from Panel Disable state, by pushing and holding “V/A
toggle”, “Take On/Off” and “Take” and then pushing “Panel Enable”. Blinking “Panel Enable” and
“Take” indicates “Restrictions Programming mode”.
All the legal inputs for the selected output are shown by orange light in button. Pushing the appropriate
input button does the Legal/Illegal toggle. When a new output is selected, the programming of the
previous output is saved in the on-board memory and the old setting of the new output is fetched from the
on-board memory.
After all necessary programming is done; pushing Panel Disable stops the programming mode.
Disabling an output completely is done by disabling all inputs for the given output. When in normal mode
these outputs may be selected for viewing the status, but not controlled.