![GRASS VALLEY OCP 400 User Manual Download Page 22](http://html.mh-extra.com/html/grass-valley/ocp-400/ocp-400_user-manual_2257538022.webp)
22
OCP 400 Operational Control Panel User’s Guide (v12.0)
Chapter 3 - Setup
3.3.1 Setting the OCP control level
The OCP menu system has three levels of control; Simple, Basic and Full. These levels
determine which functions are displayed. In the OCP setup menu move to the OCP Set item
and select S (simple), B (basic) or F (full).
•
Select the simple level to reduce the number of functions displayed to a minimum. Use
this level to protect against unintentional changes to critical parameters.
•
Select the basic level as the normal operational mode of the OCP. Use this level to prevent
set-up parameters from being displayed. This is the factory default level.
•
Select the full level to access all functions available on the OCP.
3.3.2 Camera assignment
The OCP can be assigned to an XCU/Base Station - camera combination by moving to the
CamNum item of the OCP setup menu. Select the camera number of the camera that you
want to control using the assignable rotary control. Press SELECT to confirm.
OCP setup
page 7
CamNum2
Select secondary camera
number
1..99
SELECT
Connects to the secondary
camera.
Press button to connect to the
selected secondary camera
—
Multi-Cam
Switches multi camera mode on
or off
On, Off
OCP setup
page 8
ProgFunc1
Assigns a function to
programmable function1
Disabled, Gain +/-, ND Up/Dwn,
FX Up/Dwn
ProgFunc2
Assigns a function to
programmable function 2
Disabled, Gain +/-, ND Up/Dwn,
FX Up/Dwn
—
—
OCP setup
page 9
ProgFunc3
Assigns a function to
programmable function 3
Disabled, Dtl Lvl, Var Gain, Var
Ctemp, BlackStr, BlackStr Lvl,
Knee, Knee Slope, Knee Point
ProgFunc4
Assigns a function to
programmable function 4
same as above
ProgFunc5
Assigns a function to
programmable function 5
same as above
ProgFunc6
Assigns a function to
programmable function 6
same as above
OCP setup
page 10
OCP Set
Selects the OCP control access
level
S
Simple (S), Basic (B), Full (F)
—
—
Reset OCP
Resets all local functions to
their default values.
F
Press button to execute reset
Menu
Selections
Function
Level
Possible values
Summary of Contents for OCP 400
Page 17: ...OCP 400 Operational Control Panel User s Guide v12 0 17 Chapter 2 Configurations ...
Page 18: ...18 OCP 400 Operational Control Panel User s Guide v12 0 Chapter 2 Configurations ...
Page 52: ...52 OCP 400 Operational Control Panel User s Guide v12 0 Chapter 4 Operation ...
Page 58: ...58 OCP 400 Operational Control Panel User s Guide v12 0 Chapter 6 Connectors ...
Page 59: ...OCP 400 Operational Control Panel User s Guide v12 0 59 ...