54
RollCall Control Panel
Input Spigots
Option
Operation
Spigot Pane
Displays spigot direction, associated BNC connector, current
module status, the last
Take
performed on the spigot and
how it was made, e.g. via RollCall or an external agent such as
VSM.
The following controls are also available:
•
Streaming
- set the redundancy options for this spigot.
This will also determine the bandwidth to be used.
Options are:
•
Dual
- full redundancy, both Primary and Secondary
available.
•
Single
- Primary only, but with all available
bandwidth.
•
A
- Primary only.
•
B
- Secondary only.
•
Format
- select the maximum expected bandwidth
requirement for this spigot.
Sender Pane
•
Ext Headers
- Extended header operation can be
adjusted for TR-03/TR-04 compatibility.
Extended headers provide in-band metadata regarding
the essence flow and its format, and are applicable to ST-
2110 only. If third-party equipment is unable to support
this, the functionality can be disabled, or set to
On
(Legacy)
, which ensures that the packet format complies
with ST2110 but has no video content.
• Options are:
•
Off
- Extended headers are disabled.
•
On
- Sends extended headers fully compliant with
ST2110-20.
•
On (Legacy)
- Sends extended headers that are
compatible with releases earlier than V11.73D.76.
•
Num Audio Channels
- select the number of audio
channels present on this spigot.
•
Packet Time
- select the amount of time required to
complete the transmission of each packet.
•
SDI Input CRC Errors
- enable the check box to display
the number of CRC errors. Click
Clear
to reset the
counter to zero.
•
Spigot Link
- indicates the spigot link status for the
selected spigot, as set on the
Link Control
page (see
).
Control is displayed only if spigots are linked.
Take
Click to apply changes.