55
CopperHead 3050
User Guide
the Diagnostic mode, a quick push of the Selector cycles through the various diagnostic
sub-modes described above.
The following table describes the expected readouts in each of the above Base Station
display modes. By following the sequence, you can understand what the various readouts
and four-character abbreviations mean for the system.
Display Mode
Readout
Base Station Digital Display Activity Explanation
(assumes after initial power up - see Page xx for a description of the Power Up sequence)
BASE RX (Base Station Receive Signal Strength)
BASE RX
-9
Indicates that the Base Station signal strength is -9 dBm
BASE RX
OPT
Indicates that the Display is showing Optical link signal
strength
BASE RX
-9
Repeat of the Base Station signal strength
BASE RX
OPT
Repeat that the display is showing Optical link signal
strength
This display cycle repeats itself and depending on timing
may start with either OPT of the strength measurement
CAM RX (Camera Unit Receive Signal Strength)
CAM RX
COPT
Sequence starts with COPT to indicate camera optical
signal strength
CAM RX
-9
Indicates that the signal strength from the Camera Unit is
-13 dBm
CAM RX
OPT
Indicates that the Display is showing Optical link signal
strength
Note
: the only way to distinguish between BASE RX and
CAM RX is to check the Display Mode LED indicator
CAM RX
-9
Repeat of the Camera Unit signal strength
CAM RX
OPT
Repeat that the display is showing Optical link signal
strength
This display cycle repeats itself and depending on timing
may start with either OPT of the strength measurement -
COPT does not reappear in the repeating cycle
DIAGNOSTIC MODE Temperature (TEMP)
DIAG
When first entering the Diagnostic mode the DIAG display
mode indicator LED will blink - the first sub-mode is TEMP
(Temperature). The Digital Display Characters will glow
Green when the temperature is normal and Red when
outside of normal range.
DIAG/TEMP
TEMP
Indicates the display is in the TEMP sub-mode
DIAG/TEMP
PS
The Power Supply (PS) temperature will be displayed
DIAG/TEMP
TEMP
Repeats that the display is in the TEMP sub-mode
DIAG/TEMP
37C
Temperature display in Centigrade for Power Supply
circuit board
DIAG/TEMP
BASE
The Base Station main circuit board temperature will be
displayed
DIAG/TEMP
TEMP
Repeats that the display is in the TEMP sub-mode
Summary of Contents for CopperHead 3050
Page 1: ...CopperHead 3050 User Guide M4010 9900 102 24 July 2014...
Page 6: ...vi Table of Contents...
Page 68: ...62 Operation of the System Troubleshooting...
Page 77: ...71 Camera Unit Connectors...
Page 81: ...75 Base Station 25 Pin Audio Output Cable...
Page 91: ...85 Block Diagrams Block Diagrams Fig D 5 CopperHead 3050 Functional Block Diagram...
Page 93: ...87 Low Powered Version Low Powered Version Fig D 7 CopperHead 3050 Low Powered Version...