background image

JUPITER  —  Release Notes

21

Upgrading to 7.9.0

 

Upgrading to 7.9.0

Caveats

Please read the following caveats before starting the upgrade procedure. 
During this upgrade procedure: 

All switcher status will be lost. To restore status, make note of the status 
of all outputs before starting the upgrade and re-take all switches. Or, 
you can use Router Save/Restore to restore status on Grass Valley (GV) 
routers. 

All memory on all Jupiter control system boards will be cleared after 
the installation and download process. The memory is cleared due to a 
mandatory “pmemclear“ command. 

All configuration sets will need to be recompiled. 

Equipment Required 

GV-supplied PC 3000 (F7-029500-121) file server or a PC with the following 
minimum requirements: 

Windows XP Professional - SP2 (English version)

2 GHz Pentium processor

2  GB  of  RAM

125 MB of Hard disk space for the Jupiter application

Intel or 3Com Ethernet LAN card

Keyboard and mouse

A minimum resolution of 1280 X 1024 and 32 -bit color PC monitor setting 
is recommended for proper display of the Jupiter Soft Panel and VSD 
screens. The Appearance font size on the Display Properties dialog (Con-
trol Panels> Display> Appearance: Font size drop-down list) should be set 
to Normal. Selecting either the 

Large

 or the 

Extra Large Fonts

 option will 

cause application display problems. 

Software Required 

Installation of the Jupiter 7.9.0 release is only supported on the English 
version of Windows XP Professional SP2 or later. Windows Firewall and 
any Anti-Virus Firewall must be disabled to allow the Bootp, TFTP, and JNS 
applications to operate properly. 

Summary of Contents for Control System

Page 1: ...JUPITER CONTROL SYSTEM Release Notes Software Version 7 9 0 071827513 NOVEMBER 2010 ...

Page 2: ...808 29238 Brest Cedex 3 France 40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France Spinnereistrasse 5 CH 5300 Turgi Switzerland Brunnenweg 9 D 64331 Weiterstadt Germany Carl Benz Strasse 6 8 67105 Schifferstadt Germany Including its implementation meets the requirements of the standard ISO 9001 2008 Scope The design manufacture and support of video and audio hardware and software produc...

Page 3: ...JUPITER CONTROL SYSTEM Release Notes Software Version 7 9 0 071827513 NOVEMBER 2010 ...

Page 4: ... 33 1 48 25 20 20 United States Canada 24 x 7 1 800 547 8949 or 1 530 478 4148 Local Support Centers available during normal business hours Asia Hong Kong Taiwan Korea Macau 852 2531 3058 Indian Subcontinent 91 22 24933476 Southeast Asia Malaysia 603 7805 3884 Southeast Asia Singapore 65 6379 1313 China 861 0660 159 450 Japan 81 3 5484 6868 Australia and New Zealand 61 1300 721 495 Central South A...

Page 5: ...Router Values 13 Entering Serial Protocol information 14 Pro Bel SW P 08 Interface Implementation Notes 16 P8R SW P 08 Router Control 16 P08 SW P 08 Control Panel 17 Physical Serial Interface 18 Remote PC Access is No Longer Supported 19 Spanning Tree Protocol 20 Upgrading to 7 9 0 21 Caveats 21 Equipment Required 21 Software Required 21 Materials Supplied 22 Optional Materials 22 Software Update ...

Page 6: ...6 JUPITER Release Notes Contents ...

Page 7: ...ease 7 9 0 AccuSwitch The 7 9 0 version of the Jupiter AccuSwitch Control system software has the following enhancements and changes Support for the CM 4400 Pro Bel SW P 08 Protocol The Remote PC feature is no longer supported These features provide customers with improved control convenience and flexibility when connecting and using Jupiter s control panels Each of these features is described in ...

Page 8: ...ll then appear Figure 1 The Jupiter Settings Dialog 3 Enter the Subnet Mask and Gateway IP Addresses for your system See your System Administrator for this information Note Grass Valley recommends that you enter the IP address of your Jupiter PC and use 255 255 255 0 for the Subnet Mask if there is no Gateway However only enter this information if your System Administrator does not provide the nee...

Page 9: ... the Jupiter CM 4000 or CM 4400 to use a Pro Bel SW P 08 Router Control port This is accomplished by adding entries in the Serial Protocol and MPK Devices tables For steps to configure a CM 4000 or CM 4400 or modifying compiling and validating a configuration set see the CM 4000 Control Module or the CM 4400 Control Module manuals Note These steps assume that the CM 4000 or CM 4400 has been config...

Page 10: ...xample of the Serial Protocol Table 2 Double click the protocol box that is associated with the Serial port A drop down list will show the possible protocol types 3 Select the P08 SW P 08 Control Panel protocol 4 Click anywhere else in the table to close the entry The default Baud rates will be selected automatically however the Baud rate may be changed by clicking the drop down menu Figure 4 Figu...

Page 11: ...s The MPK Devices table will then open 2 Enter a name in the MPK Devices column 3 Click the Device Type drop down list and then select the Serial option 4 Click the Board drop down list and then select the preferred board 5 Enter the Port number in the Port column 6 Select the Input Sets drop down list and then select the preferred Serial input set 7 Select the Output Sets drop down list and then ...

Page 12: ... Description table as 100 If the Pro Bel remote router also uses level 0 it would be entered as 200 in the PLvl field A hardware Level setting of 1 on the Datatek switcher could be entered on this table as 101 This offset eliminates the need to re set existing level settings on the hard ware The Protocol matrix and Level are both set by the Jupiter system s Physical level value which ranges from 0...

Page 13: ...ee Table 2 Remote Router Values As stated earlier all Remote Router Physical level values are offset The Pro Bel SW P 08 remote router physical level value is offset by 100 The fol lowing table shows the Matrix and Level values for a given PLVL Table 2 Remote Router Values for Physical Level 0 99 Matrix and Level PLvl Matrix Level PLvl Matrix Level PLvl Matrix Level 0 0 0 36 2 4 72 4 8 1 0 1 37 2 ...

Page 14: ...me of the Configuration set Ensure that the configuration set that is opened is the one that you want to change Follow these steps to enter or modify the Serial Protocol table 1 Select the Serial Protocol option from the Jupiter menu Jupiter Serial Protocol The Serial Protocol table will then open Figure 3 14 0 14 50 3 2 86 5 6 15 0 15 51 3 3 87 5 7 16 1 0 52 3 4 88 5 8 17 1 1 53 3 5 89 5 9 18 1 2...

Page 15: ...Select the P8R SW P 08 Router Control protocol 4 Click anywhere in the table accept the entry The Baud rates will be selected automatically Figure 4 The Baud rate can be changed by clicking the drop down list in the Baud rate column Figure 8 The P8R SW P 08 Router Control Protocol on The Serial Protocol Table 5 Click the Apply button and then save your changes 6 Compile and activate the Configurat...

Page 16: ...Bel SW P 08 level value is from 0 to 15 and the Pro Bel SW P 08 matrix value is from 0 to 6 which is the physical level divided by 16 A Jupiter system TAKE command will send a Pro Bel CONNECT mes sage which is confirmed when a CONNECTED message is received immediately following the CONNECT message The interface will re send a CONNECT message up to three more times after an error or if the CONNECTE...

Page 17: ...ONNECTED message only when the cross point is valid Unsolicited CONNECTED messages will be sent for confirmed TAKES to outputs in the control panel set Commands are repeated up to 3 times when a NAK error occurs Table 5 P08 SW P 08 Control Panel Received Information Message Value CONNECT 2 CONNECT_EXT 130 INTERROGATE 1 INTERROGATE_EXT 129 CONNECTED 4 CONNECTED_EXT 132 Single source name request 10...

Page 18: ...be the configuration Figure 9 Serial Cable Pin out Table 7 Control Module RS 422 485 Female 9 pin Configuration Pin Configuration 1 GND 2 RX 3 TX 7 RX 8 TX Table 8 PC RS 232 Male DTE pin Configuration Pin Configuration 5 GND 2 RXD 3 TXD 071827512_Pro bell Serial connections 1 6 R 2 7 3 T 8 4 9 5 R RS 422 485 female RS 232 DTE male 1 6 2 7 3 8 4 9 5 T R G G T ...

Page 19: ...more Grass Valley assumes no responsibility or liability for any continued use of this feature the user of this feature assumes all risk and liability including without limitation lost profits business interrup tion or lost information The Configure menu and the File Server Remote PC button was removed in the 7 8 2 version of Jupiter this feature was reinstated to the JNS Control Console in the 7 ...

Page 20: ... be configured to the auto negotiate mode Using the Spanning Tree protocol will cause port latency on the switch when a device reboots and this will cause Jupiter network problems Grass Valley assumes no responsibility or liability for use of the Spanning Tree protocol the user of this protocol must assume all risk and liability as mentioned previously in Remote PC Access is No Longer Supported on...

Page 21: ...PC with the following minimum requirements Windows XP Professional SP2 English version 2 GHz Pentium processor 2 GB of RAM 125 MB of Hard disk space for the Jupiter application Intel or 3Com Ethernet LAN card Keyboard and mouse A minimum resolution of 1280 X 1024 and 32 bit color PC monitor setting is recommended for proper display of the Jupiter Soft Panel and VSD screens The Appearance font size...

Page 22: ...0 Installation and Operating Manual VM 3000 Jupiter CM 4000 Installation and Operating Manual Jupiter CM 4400 Installation and Operating Manual L S and LCD Series Jupiter Control Panels Manual Manual available online contact Technical Support for more information AccuSwitch Soft Panels and Visual Status Display Software Update CAUTION During the software update your Jupiter system will be taken of...

Page 23: ... Jupiter Systems This procedure is for updating an existing Jupiter system that has been pre viously installed completely configured and is operating correctly New Jupiter systems ship from the factory with the latest version of software pre installed New systems do not need their software updated However new Jupiter systems will need to be configured to operate at your facility ...

Page 24: ...gram will check to see if an earlier version of Jupiter is installed on the computer The earlier version will be removed before the latest version will be installed You will need to start the Installation program again after the earlier version has been removed To start the update process and remove the previous version 1 Insert the Jupiter System Software CD into the PC If the Installation Progra...

Page 25: ...Remove the program screen will then appear after a few minutes Figure 12 Figure 12 Welcome Remove the Program Screen 2 Click the Next button The Setup Status screen will then appear Figure 13 Figure 13 Setup Status Screen The previous version of the application will then be removed ...

Page 26: ...he Finish button The InstallShield Wizard application will then close You can now install the latest version of Jupiter Installing the Latest Version Note To help ensure any hidden activity is stopped you should restart the com puter Before you begin the installation process make sure that you close all Jupiter programs on the configuration PC and disable any virus protec tion programs or firewall...

Page 27: ...ble click the Setup exe icon on the CD The Jupiter Installation Welcome screen will then be displayed Figure 15 Figure 15 Jupiter Installation Welcome Screen 2 Click the Next button The Customer Information screen will then appear Figure 16 Figure 16 Customer Information 3 Enter your User Name Company Name and the Soft Key in their respective fields Note The Soft key can be found on the plastic ca...

Page 28: ...nse Agreement 6 Click the Yes button to accept the license agreement The Setup Type screen will then appear Figure 18 Figure 18 Setup Type Screen 7 Select the preferred type of installation and then click the Next button The Question dialog will then appear Figure 19 You will need the Part Number Revision letter on the MCC 3500 Control Panel Logic board For example in figure below the part number ...

Page 29: ...stem The Choose Destination location screen will then appear Figure 20 Figure 20 Choose Destination Location Screen 9 Browse to the Destination folder of your choice and then click the Next button The Enter Network Information dialog will then appear Figure 21 Figure 21 Enter Network Information Screen 10 Select the IP address for the Network card that will communicate with the Jupiter system ...

Page 30: ...t button Note You must set the Subnet Mask and Gateway IP addresses to run the 7 9 version of Jupiter on the CM 4400 See Setting the Subnet Mask and Gateway IP Addresses on page 8 for more information Using DHCP If you are using DHCP that is your IP address is not static you will see the following Question dialog Figure 22 Figure 22 Question Dialog Note It is strongly recommended that you use a St...

Page 31: ... screen will appear Figure 23 Figure 23 Start Copying Files Screen 1 Review the Current Settings and then click the Next button The Setup Status screen will then appear Figure 24 Figure 24 Setup Status Screen When the Installation process is completed the InstallShield Wizard Complete screen will then appear Figure 25 ...

Page 32: ...32 JUPITER Release Notes Version 7 9 0 Figure 25 InstallShield Wizard Complete Screen 2 Click the Finish button The installation process is now completed ...

Reviews: