JUPITER — Release Notes
17
Pro-Bel SW-P-08 Protocol
P08 (SW-P-08 Control Panel)
The P08 (SW-P-08 Control Panel) driver will receive the following:
The P08 (SW-P-08 Control Panel) sends the following:
When the P08 (SW-P-08 Control Panel) driver is used, the following will
occur:
•
The control panel level value is a combination of the Pro-Bel SW-P-08
matrix and level values. The level is the matrix times 16 plus the level.
•
The interface ACKS all messages that are received correctly even if they
are not implemented.
•
The system responds to a CONNECT message with a CONNECTED
message only when the cross point is valid. Unsolicited CONNECTED
messages will be sent for confirmed TAKES to outputs in the control
panel set.
Commands are repeated up to 3 times when a NAK (error) occurs.
Table 5. P08 (SW-P-08 Control Panel) Received Information
Message
Value
CONNECT
2
CONNECT_EXT
130
INTERROGATE
1
INTERROGATE_EXT
129
CONNECTED
4
CONNECTED_EXT
132
Single source name request
101
Single destination name
request
103
Single source name extended
229
Single destination name
extended
231
Table 6. P08 (SW-P-08 Control Panel) Sent Information
Message
Value
TALLY
3
TALLY_EXT 131
CONNECTED
4
CONNECTED_EXT
132
Source name response
106
Destination name response
107
Source name response
extended
234
Destination name response
extended
235