18
8920ADC Instruction Manual
Configuration
Local Onboard Module Configuration
The 8920ADC module can be configured locally to set parameters using the
jumpers, the rotary switch and two toggle switches shown in
. The
CONF LED indicates status of the configuration process.
These components perform the following:
•
Jumper JP7 – sets control mode for Local only or Remote and Local.
•
Jumpers JP5 and JP6 – set coarse input level adjustment for left and
right channels as explained in
Setting Maximum Operating Level
•
SW2 and SW3 (toggle) switches – provide fine adjustment of the left
and right channel input levels as described in
.
•
Function (rotary) switch – selects a desired output configuration (0
through 9, A through F), although not all positions are used.
•
CONF (configuring) LED – when on, indicates the module is initial-
izing or processing configuration information.
Note
Function switch positions 0 and F (Factory defaults) can be used to return the
module configuration to the original factory settings.
Figure 5. Module Configuration Switches and LEDs
SW2 – Left In Level
SW3 – Right In Level
CONF (yellow)
0595_05r1
JP7
LOCAL –
REMOTE –
jumper across these pins
(1 – 2) locks out remote control
jumper across these pins
(2 – 3) enables remote
and local control
Remote Control Lockout
JP5
Pins
Pins
JP5
JP7
JP6
JP6
Coarse Level Setting
1-2 2-3 4-5 5-6
1-2 2-3 4-5 5-6
1
3
SW1 – Function Rotary Switch