4-6
Function Settings and Operations
(3) Press the
(ENTER) key
to display the wear-rate setting submenu.
S E T B L A D E G R O U P
(4) Press the
(ENTER) key
to display the wear-rate group setting.
G R O U P 1 1 2 4 5
(5) The number on the left is the group number, and the numbers to the right of this
indicate the setting areas belonging to it, separated by spaces. The display above
indicates setting areas 1, 2, 4, and 5, belonging to group 1.
Use the
or
key
to move the cursor to the group number or setting-area
number to be set. Pressing the
or
key
at the group-number position
increases or decreases the number, and pressing the
or
key
at the
setting-area number position displays or doesn't display the number. Select the
required group number, display the setting-area numbers to be registered, and
then press the
(ENTER) key
to confirm.
Each setting area can only be registered in one group. To register a setting area
in another group, it must first be removed from the group in which it is registered.
Initially, setting area 1 is set to group 1, setting area 2 to group 2, and so on, so
setting areas must be removed from one group before being registered in
another.
To cancel the selection(s), press the
(NEXT)
or
(PREV.) key
.
Setting Wear-Rate Factors
This sets factors corresponding to the differences in wear rates due to different
materials and cutting conditions.
(1) Press the
(PAUSE) key
to switch to PAUSE mode.
(2) Press the
(NEXT)
or
(PREV.) key
until the following menu is displayed.
B L A D E W E A R S E T U P
(3) Press the
(ENTER) key
to display the wear-rate setting submenu, and
then press the
(NEXT)
or
(PREV.) key
until the following menu is
displayed.
F A C T O R
(4) Press the
(ENTER) key
to display the wear-rate factor setting.
C O N D 1 1 . 0 0
(5) Use the
or
key
to increase or decrease the setting-area number, and use the
or
key
to increase or decrease the factor value. The factor can be set to
between 0.10 and 1.00 in 0.10 intervals, and between 1.00 and 2.50 in 0.25
intervals. Once the wear-rate factor is set, press the
(ENTER) key
to confirm. To
cancel the selection(s), press the
(NEXT)
or
(PREV.) key
.
(6) Press the
(PAUSE) key
to cancel PAUSE mode.
Clearing the Total Distance (Wear Rate)
Always zero the total-distance display when a cutter blade has been replaced. This
starts the total-distance calculation from zero.
(1) Press the
(PAUSE) key
to switch to PAUSE mode.