3
Installa
tion & Specifi
ca
tion
Please Note:
This product should only be installed by a
qualifi ed electrician or competent heating installer, and
should be in accordance with the current edition of the
IEEE wiring regulations.
Specifi cation
230V model
24V model
Power supply
230 Vac,
±15%,
50/60 Hz
24 Vac,
±15%,
50/60 Hz
Switching action
2 x SPDT internally linked,
Type 1B
Unit switch rating
230 Vac,
3(1)A
24Vac,
3(1)A
Battery back-up
24 hours minimum
Programme resolution
± 1 minute
Dimensions, mm (W, H, D)
135 x 88 x 32
Design standard
EN 60730-2-7
Control Pollution Situation
Degree 2
Rated Impulse Voltage
2.5 kV
Ball Pressure Test
75°C
Product specifi cation
Installation Instructions
Installation
Remove wallplate from unit by unscrewing the two screws
on the bottom edge of the unit.
From the top left hand corner of the wallplate, there must
be clearances of at least 140 mm to the right, 15mm to the
left, 30mm above and 100mm below in order to mount the
plug-on module.