Commissioning Report
2
For use with Kerosene* only.
After installing the boiler leave these
instructions with the User.
This appliance is deemed a controlled
service and specific regional statutory
requirements may be applicable.
*Operation on Bio-fuel
All Grant Vortex Pro condensing boilers,
manufactured since May 2011, are
suitable for operation on both standard
kerosene (Class C2 to BS2869) and
also bio-kerosene – up to a 30% blend
(B30K).
All burner settings and nozzle sizes (as
detailed in Section 2.3 of this manual)
are correct for both standard kerosene
and bio-kerosene (B30K).
In order to operate this boiler on
bio-kerosene it will be necessary to
take the following actions:
a) Use a bio-kerosene (B30K)
compatible flexible oil line in place of
the oil line supplied with this boiler.
b) Have your oil storage tank and oil
supply line (including all pipework,
sight gauges, filters, isolating valves,
fire valves, de-aeration devices, etc.)
checked for their compatibility with
bio-kerosene (B30K).
Where necessary some, or all, of these
items may have to be replaced with a
bio-kerosene compatible alternative.
c) Check the suitability of the flue
system with Grant UK.
d) Use only bio-kerosene (B30K) that
conforms to OPS24.
IMPORTANT
Under no circumstances should the
boiler be used with bio-kerosene
without the above actions being taken
first.
Date:
Commissioning engineer:
Tel. No:
Boiler model:
Boiler output:
kW
Fuel type: Kerosene
Nozzle size:
Pump pressure:
Air setting:
Flue gas % CO
2
:
Net flue gas temp:
Smoke No:
System flushed: Yes / No
Corrosion inhibitor added: Yes / No
Antifreeze added: Yes / No
(where there is a Yes / No - please circle appropriate answer)
Grant EnGinEErinG (UK) LimitEd
Hopton House, Hopton Industrial Estate, Devizes, Wiltshire SN10 2EU
Tel: 01380 736920 Fax: 01380 736991
Email: [email protected] www.grantuk.com
This manual is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or
appearances are changed in the interests of continued product improvement.
All good sold are subject to our official Conditions of Sale, a copy of which may be obtained on application.
© Grant Engineering (UK) Limited 2016. No part of this manual may be reproduced by any means without prior written consent.
For sealed systems only:
Expansion vessel size :
litres
Expansion vessel change pressure :
bar
Sealed system fill pressure (cold) :
bar
Service Log
It is recommended that the boiler should be regularly serviced, at least once a year,
and the details entered in the Boiler Handbook by the service engineer.