44
12. Focus Adjustment & Hardware Reset
12.1 Camera Focus Adjustment
NOTE:
The focus of network camera is set at the factory. If focus adjustment is required, please follow
the steps below to adjust the focus.
Step1.
Open the lens cover.
Step2.
Remove the three screws
and carefully remove the IR LED board.
Step3.
Unscrew the fixed ring around the lens. Adjust the focus ring until the image is clear, and then
tighten the fixed ring.
45
12.2 Hardware Reset
If you forget your password, you must reset the network camera to the default settings.
Step1.
Open the lens cover and remove the IR LED board (refer to section 12.1).
Step2.
Remove the three HEX standoffs.
Step3.
Carefully pull the metal plate out.
Step4.
Press and hold the “Default” button until the Status LED turns off (it may take about 10 seconds),
then release the button.
Step5.
When the Status LED displays green, the network camera is reset to the factory default settings.