HandTone-496 User Manual
Grandstream Networks, Inc.
22
WAN side http
access:
No
Yes (WAN side access to http server will be rejected if set to
No)
Update
All Rights Reserved Grandstream Networks, Inc. 2005
Admin Password
This contains the password to access the Advanced Web Configuration page.
This field is case sensitive.
SIP Server
SIP Server’s URI or IP address
Outbound Proxy
SIP Outbound Proxy Server’s URI or IP address
SIP User ID
SIP service subscriber’s User ID
Authenticate ID
SIP service subscriber’s Authenticate ID. Can be identical to or different from
SIP User ID
Authenticate
Password
SIP service subscriber’s account password
Name
SIP service subscriber’s name which will be used for Caller ID display
Register Expiration
This parameter allows the user to specify the time frequency (in minutes) the
HandyTone ATA refreshes its registration with the specified registrar. The
default interval is 60 minutes (or 1 hour). The maximum interval is 65535
minutes (about 45 days).
Local SIP port
This parameter defines the local SIP port the HandyTone ATA will listen and
transmit. The default value for FXS port 1 is 5060. The default value for FXS
port 2 is 5062.
Local RTP port
This parameter defines the local RTP-RTCP port pair the HandyTone ATA will
listen and transmit. It is the base RTP port for channel 0. When configured,
channel 0 will use this port _value for RTP and the por1 for its RTCP;
channel 1 will use por2 for RTP and por3 for its RTCP. The
default value for FXS port 1 is 5004. The default value for FXS port 2 is 5008.
Enable Call
Features
Default is No. If set to Yes, Call Forwarding & Do-Not-Disturb are supported
locally
Send DTMF
This parameter controls how DTMF events are transmitted. There are 3 ways:
in audio which means DTMF is combined in audio signal (not very reliable
with low-bit-rate codec), via RTP (RFC2833), or via SIP INFO.
DTMF Payload
Type
This parameter sets the payload type for DTMF using RFC2833