![grandimpianti GWH Series Instructions For Use And Maintenance Manual Download Page 45](http://html.mh-extra.com/html/grandimpianti/gwh-series/gwh-series_instructions-for-use-and-maintenance-manual_2255200045.webp)
45
INST
ALLA
TION, CONNECTIONS, AND ADJUSTMENTS
• at least 500 mm of free space between the appliance and the rear wall;
• at least 50 mm of free space between appliance side and side wall or other appliance.
Moreover, check that:
• the electric absorption of the appliance is lower than that supplied by the electric company;
• the steam and water pressure available (for appliances provided with this type of heating) are within the accepted values.
Below we indicate the accepted values for models GWM/ GWN:
Model
Max. floor static
load (kN)
Dynamic floor load
(kN)
Dynamic load
frequency (Hz)
Max. water
pressure (KPa)
Max. steam
pressure (KPa)
kg 8
1.9
1.6 ± 2.4
13.7
800
600
kg 11
2.2
1.9 ± 4.0
12.7
kg 14
2.7
2.2 ± 5.1
12.7
kg 18
3.4
2.7 ± 3.6
8.2
Kg 24
3.9
3 ± 4.8
8.2
Kg 28
4.2
3.22 ± 5.6
8.2
Allowed values for the GWH models:
Model
Max. floor static
load (kN)
Dynamic floor load
(kN)
Dynamic load
frequency (Hz)
Max. water
pressure (KPa)
Max. steam
pressure (KPa)
kg 8
2.3
1.9 ± 0.5
19.4
800
600
kg 11
2.6
2.2 ± 0.5
17.9
kg 14
3.2
2.7 ± 0.5
17.9
kg 18
4.9
4.0 ± 0.7
16.3
Kg 24
5.3
4.6 ± 1.1
16.3
Kg 28
5.8
5.0 ± 1.1
15.25
Prepare some wall taps at a distance that must not exceed the length of the supplied pipes.