![GRAND EFFECTS FPIAUT24 Operation And Maintenance Manual Download Page 6](http://html.mh-extra.com/html/grand-effects/fpiaut24/fpiaut24_operation-and-maintenance-manual_2254978006.webp)
Page 6
24” - 30” Fire Pit Inserts
Standard Line Automated Operation
Additionally, Zodiac Pool Systems LLC, requires that as required by Article
680 of the NEC, the appliance be properly connected to an equipotential
bonding grid/loop that includes all electrical equipment in the system and
on the equipment pad. Bonding lugs must be connected with a solid copper
wire at least 8 AWG (6 AWG in Canada) or larger. Failure to do so may void
the Zodiac Pool Systems LLC warranty.
CAUTION
To prevent premature failure of the appliance resulting from stray
voltages and voltage differentials, the burner must be bonded to
other equipment which is part of the pool plumbing system with a
solid copper wire not smaller in diameter than 8 AWG (6 AWG) in
Canada).
BONDING THE BURNER
Note:
The Burner insert contains a bonding lug near the pilot on the
bottom.
1.
Loosen the setscrew.
2.
Insert the bond wire into the hole.
3.
Tighten the setscrew until the bond wire is secured into place.
Bonding Lug /
Bond Wire Insert
Setscrew
Figure 1. Bonding Lug on Burner Assembly