5
FLUE PIPE CONNECTION
GasFired boilers (
CHIMNEY ONLY applications)
CLEANOUTS
Rear removable smoke hood cover & Combustion Front Door Opening
FUEL
GasFired Natural Gas or Liquefied Petroleum Gas LPG
ELECTRICAL
CANADA : 120 Volts, 60Hz,15 amps fuse or breaker
USA : 13.3 amps, circuit protection 20 amps.
AIR SUPPLY
CAUTION: Adequate air supply for both combustion and ventilation must be available.
See page 17 for details.
3.0 Unit installation
3.1 PLACEMENT & LEVELING OF THE UNIT
The boiler should be located on firm foundation in an easily accessible area that meets the
previously discussed clearances and air requirements. In situations where the floor may be
uneven the unit may be levelled by using the leg levellers provided on the boiler or through the
insertion of shims under the legs.
3.2 JACKET ASSEMBLY AND CONTROL INSTALLATION
The boiler jacket has been designed for ease of assembly and removal. The following step-by-
step process will ease installation. A screwdriver, 17 mm socket and ratchet or a 17 mm
wrench or adjustable wrench are needed.
Adjustable
Leg Leveler
Rail