2.0 PRODUCT INFORMATION
PHYSICAL DIMENSIONS
Length
: ( 3 sections 18 7/8 ‘’ ) ( 4 sections 22 1/2’’ ) ( 5 sections 26 ¼’’ )
( 6 sections 31 1/8’’ ) ( 7 sections 35 ½’’) ( 8 sections 39 ¼’’)
CLEARANCE
Proper clearances must be maintained not only from combustible materials but also to provide
adequate access for servicing. All installations must comply with local codes and CSA B149.1
(gas) in Canada and NFPA 54 (gas) in the United States. Consult local fire codes for required
clearances. Connections to chimney must be made with the proper gauge thickness and
diameter of fluepipe as required by CSAB149.1,NFPA 54, whichever is applicable.
CLEARANCE (minimum) FOR SERVICING –
Gas
Front
24” (609 mm)
Rear
24” (609 mm)
Left Side
24” (609 mm)
Right Side
2” (50.8 mm)
Top
10” (254 mm)
CLEARANCE (minimum) TO COMBUSTIBLES –
Gas
Top
10” (254 mm)
Front
24” (609 mm)
Rear
24” (609 mm)
Left Side
24” (609 mm)
Right Side
2” (50.8 mm)
Chimney Connector
9” (229 mm)
SPECIFIC TO GASFIRED BOILERS
*** A gasfired boiler must NOT be installed on carpeting.
DRAFT PRESSURE
Breech draft pressure -0.02’’ w.c. – Gas-Fired Boiler