765041982
Rev. 000
23
Dry cooling
DRY
Dry cooling function may only be selected via the user menu.
The user menu is opened by pressing the button
for
approx. 3 seconds. The function can now be switched in or out
under the DC menu item, saved with
P
, after which the menu
is exited with
.
Menu item
Description
Settings range
Factory
setting
DC
Dry cooling function *
Activation : ”ON”
Deactivation: "OFF"
OFF
Alarm and error messages on the display
Display
Explanation
OP
The door is open (or the door switch is closed in another manner).
A1
Door alarm ”dA” was activated.
A2
Local alarm, maximum value was activated (LHL)
F1
Room temperature sensor is defective. The sensor must be replaced by
the service department. The cabinet will still approximately maintain the
preset temperature with the use of an emergency program.
F2
If ”F2” is shown, the evaporator sensor is defective, or there is extreme
icing up of the evaporator. Initially, the unit must be completely defrosted
one single time (disconnected, after which the cabinet must stand with an
open door for 24 hours)
, Important - condensation container under the
unit may run over in connection with this!).
If the fault subsequently
continues to be displayed, then the service department must replace the
sensor a quickly as possible. The preset temperature will continue to be
maintained, and the defrosting phase will occur gradually without
temperature restrictions.
Summary of Contents for BAKER SF 550
Page 1: ...765041982 Rev 000 1 Operating and servicemanual BAKER SF 550 PROCESS KP 60 KP 82...
Page 7: ...765041982 Rev 000 7 Min 40 mm...
Page 12: ...765041982 Rev 000 12 Fig 5...
Page 33: ...765041982 Rev 000 33 Changing the door hinge side 1 2 3 4...
Page 34: ...765041982 Rev 000 34 5 6 7...
Page 35: ...765041982 Rev 000 35 8 9 10 11 12 13 14...
Page 36: ...765041982 Rev 000 36 15 16...
Page 37: ...765041982 Rev 000 37 17 18 19 20...
Page 38: ...765041982 Rev 000 38 21 22 23...
Page 39: ...765041982 Rev 000 39 Wiring diagram KP 82...
Page 40: ...765041982 Rev 000 40 Wiring diagram SF 550 KP 60...
Page 41: ...765041982 Rev 000 41 Piping diagram KP 82...
Page 42: ...765041982 Rev 000 42 Piping diagram SF 550 KP 60...