765041982
Rev. 000
21
Thawing program
In connection with thawing, a defrosting heating element is used,
which is governed by the temperature that the room sensor measures.
The thawing program is only able to start when the desired
temperature value is set to b2
C and +8
C.
The program is started by pressing the button
.
starts the function.
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is
commenced (if such is required based
upon the evaporator sensor's
temperature). Afterwards, the storage
program is switched to.
Manual defrosting of the evaporator
Manual defrosting is only possible as initial defrosting:
Start
a
program:
Press
on
(wait
for
10
seconds).
Press
on
in
order
to
end/interrupt
the
program
again.
This
then
causes
defrosting
to
be
commenced
Do not use pointed or sharp objects to make defrosting go faster!
Automatic defrosting of the evaporator
The unit performs automatic defrosting 1 to 8 times daily, when the "PCL",
"HCL" and "SCL" programs have finished.
Defrosting cannot be concluded
manually! In connection with this, the internal temperature inside the unit is
shown before the defrosting process commences.
Summary of Contents for BAKER SF 550
Page 1: ...765041982 Rev 000 1 Operating and servicemanual BAKER SF 550 PROCESS KP 60 KP 82...
Page 7: ...765041982 Rev 000 7 Min 40 mm...
Page 12: ...765041982 Rev 000 12 Fig 5...
Page 33: ...765041982 Rev 000 33 Changing the door hinge side 1 2 3 4...
Page 34: ...765041982 Rev 000 34 5 6 7...
Page 35: ...765041982 Rev 000 35 8 9 10 11 12 13 14...
Page 36: ...765041982 Rev 000 36 15 16...
Page 37: ...765041982 Rev 000 37 17 18 19 20...
Page 38: ...765041982 Rev 000 38 21 22 23...
Page 39: ...765041982 Rev 000 39 Wiring diagram KP 82...
Page 40: ...765041982 Rev 000 40 Wiring diagram SF 550 KP 60...
Page 41: ...765041982 Rev 000 41 Piping diagram KP 82...
Page 42: ...765041982 Rev 000 42 Piping diagram SF 550 KP 60...