22
SET-UP PROCEDURES
The Vari Speed S1000 has been set up at the factory to satisfy
most application needs. You may, however, wish to tailor your
control specifically to your application requirements. If so, follow
these instructions for proper set-up.
FACTORY SETTINGS
MIN SPEED
Zero volts
MAX SPEED
90VDC Output for
120 VAC line
180VDC Output for
240 VAC line
Current Limit (CL)
100% of Control Rating
IR Compensation
Set for no compensation
ACCEL
Minimum
DECEL
Minimum
NOTE: Before making any adjustments, start control and run
motor fully loaded for at least 30 minutes so motor temperature
will stabilize. (Motor speed will increase as temperature
increases).