Graham-Patten Avenue 6010 Manual Download Page 6

MODULE CONFIGURATION AND CONTROL

The parameters for each Avenue module must be configured after installation. This can be
done remotely using one of the Avenue remote control options or locally using the module
front panel controls. Each module has a 

REMOTE/LOCAL

switch on the front edge of

the circuit board which must first be set to the control mode you will be using.

The configuration parameter choices for the module will differ between 

Remote

and

Local 

modes. In 

Remote

mode, the choices are made through software and allow more

selections. The 

6010 Parameter Table

below summarizes and compares the various con-

figuration parameters that can be set remotely or locally and the default/factory settings.

If you are not using an remote control option, the module parameters must be configured
from the front panel switches. Parameters that have no front panel control will be set to a
default value. The 

Local

switches are illustrated in the 

Front Panel Controls and

Indicators

section following the 

6010 Parameter Table

.

Avenue module parameters can be configured and controlled remotely from one or both of
the remote control options, the Avenue Touch Screen or the Avenue PC Application. Once
the module parameters have been set remotely, the information is stored on the module
CPU. This allows the module be moved to a different cell in the frame at your discretion
without losing the stored information. Remote configuration will override whatever the
switch settings are on the front edge of the module.

For setting the parameters remotely using the Avenue PC option, refer to the 

Avenue PC

Remote Configuration

section of this document.

For setting the parameters remotely using the Avenue Touch Screen option, refer to the

Avenue Touch Screen Remote Configuration

section of this data pack following

Avenue PC.

Model 6010 Four Channel 20-bit Audio ADC

6010-6

Ch 1/2 Mode
Ch 3/4 Mode

CH 1-4 Digital Ref

Ch 1-4 Analog Ref 

2-Channel
Stereo
Quad Tracking

-20 dBFS
-18 dBFS
-16DBFS
(Ch 1-4 Quad Tracking, 
Ch 1/2 and/or 3/4 stereo pair or 
individual channel adjustment)

-10dBu to +8dBu
(Ch 1-4 Quad Tracking, 
Ch 1/2 and/or 3/4 stereo pair or 
individual channel adjustment)

 No Adjustment
 

AB Switch:  00 for -20 dBFS
                    01 for -18 dBFS
                   10 for -16 dBFS

Shaft Encoder: 
-10dBu to +8dBu 

Quad Tracking

N/A

N/A

CONTROL 

REMOTE 

LOCAL 

DEFAULT VALUE

6010 Parameter Table

Summary of Contents for Avenue 6010

Page 1: ...he module information in this data pack is organized into the following sections Module Overview Applications Installation Cabling Module Configuration and Control Front Panel Controls and Indicators...

Page 2: ...e a rotary control to set the analog input reference level and a set of switches to set the digital output reference level Both of these reference levels determine the analog input gain The on board m...

Page 3: ...n this application a 6010 module converts four channels of analog audio from a video routing switcher to digital to feed a digital VTR A 6030 Video Referenced AES Word Clock Generator module provides...

Page 4: ...ovide a video locked AES reference for the 6010 is optional and is recommended in video applications Driving a 6010 Using a Single ended unbalanced Source The 6010 has balanced transformerless inputs...

Page 5: ...module locations This module may be hot swapped inserted or removed without powering down or disturbing performance of the other modules in the system CABLING Refer to the backplane diagram of the mo...

Page 6: ...d controlled remotely from one or both of the remote control options the Avenue Touch Screen or the Avenue PC Application Once the module parameters have been set remotely the information is stored on...

Page 7: ...ON or absence OFF of power 5V CPU green LED OFF A power fault or halted CPU ON A halted CPU FAST BLINK CPU Run error SLOW BLINK System OK If SPI control is active from the main frame System Control M...

Page 8: ...endent of each other Adjustments may be made to each channel individually and will not affect the other channels Menu selections are provided for each channel as shown in the following section You may...

Page 9: ...2 Channel this will adjust Channel 2 Digital Output Reference level only If Ch 1 2 Mode is set to Stereo adjustment will affect the stereo pair or if set to Quad Tracking adjustment will affect all c...

Page 10: ...t Reference level from 10dBu to 8dBu in 0 5dBu steps for channel 3 only in 2 Channel mode If Ch 3 4 Mode is set to Stereo adjustment will affect the stereo pair or if set to Quad Tracking adjust ment...

Page 11: ...ls to 10dBu to 8dBu in 0 5dBu steps NOTE Digital and Analog Ref settings above will only be active when Quad On is checked The following indicators are available in the menu below Sampling Frequency w...

Page 12: ...uad Tracking Ch 1 Digital Ref sets the Digital Output Reference level to match the studio reference for channel 1 in 2 Channel mode Ch 1 2 if in Stereo mode or all four channels together if in Quad Tr...

Page 13: ...Ch 1 2 Mode is set to 2 Channel this will adjust Channel 2 Digital Output Reference level only If Ch 1 2 Mode is set to Stereo adjustment will affect the stereo pair or if set to Quad Tracking adjustm...

Page 14: ...e Digital Output Reference level for Channel 3 in 2 Channel mode If Ch 3 4 Mode is set to Stereo adjustment will affect the stereo pair or if set to Quad Tracking adjustment will affect all channels C...

Page 15: ...is set to 2 Channel this will adjust Channel 4 Digital Output Reference level only If Ch 3 4 Mode is set to Stereo adjustment will affect the stereo pair or if set to Quad Tracking adjustment will af...

Page 16: ...ls to 10dBu to 8dBu in 0 5dBu steps NOTE Digital and Analog Ref settings above will only be active when Quad On is checked The following indicators are available in the menu below Sampling Frequency w...

Page 17: ...em Control module is present If not try removing it and plugging it in again System Control module may not be working properly if installed No AES signal out of module Check cabling to input of module...

Page 18: ...s Factory Service If you return equipment for repair please get a Return Material Authorization Number RMA from the factory first Ship the product and a written description of the problem to Ensemble...

Page 19: ...Reference Level 16 18 20dBFS AES3id reference input 1 volt p p terminated in 75 ohms AES outputs 1 volt p p 75 ohm source terminated Sample Rate 48kHz or External 30 50kHz Frequency Response 0 0 1dB...

Reviews: