background image

HP_4E2-INS-LAB-RevA21 26

7  GF HEALTH PRODUCTS, INC. LIMITED WARRANTY FOR HAUSTED BRAND 

STRETCHERS AND CHAIRS 

SCOPE OF WARRANTY

GF Health Products, Inc. (“GF”) warrants to the original purchaser only that it will replace or repair components, at GF’s sole discretion, that 

are defective in material or workmanship under normal use and service. All warranties are conditioned upon the proper use and maintenance 

of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals . To the extent that a 

component is warranted by a third party, GF conveys all of its rights under that warranty to the original purchaser, to the extent permitted.
This limited warranty shall only apply to defects that are reported in accordance with the provisions set forth in this warranty document 

within the applicable warranty period and which, upon examination by GF or its authorized representative, prove to be a warranty item. This 

limited warranty is not transferable.
The warranted components and time period are set forth below :

 COMPONENT .......................................................................PARTS WARRANTY ...... LABOR WARRANTY*

 Frame ......................................................................................... 5 years .............................1 year 
 Casters ....................................................................................... 1 year ...............................1 year 
 

Electrical components ............................................................. 1 year ...............................1 year 

 Hydraulics ................................................................................. 1 year ...............................1 year 
 

Optional accessories ............................................................... 1 year ...............................1 year 

 

Patient weighing system ......................................................... 1 year ...............................1 year 

 

Pneumatic gas springs ............................................................. 1 year ...............................1 year 

 

Upholstered pads ..................................................................... 1 year ...............................1 year

 

Replacement parts** ............................................................... 90 days

 * The Labor Warranty applies only to products purchased within the U.S. Labor is not warranted for products purchased outside the U.S.
 

**  The warranty period is as designated above. If a part is replaced under warranty, the original warranty period will not be affected. 

 

All other replacement parts will be subject to the warranty period specified.

The applicable warranty period shall commence from date of shipment to the original customer, unless there is an expiration date on the 

component in which case the warranty shall expire on the earlier of warranty period or the expiration date.

OBTAINING WARRANTY SERVICE

Obtaining Warranty Service Inside the U.S.:

 A GF Customer Service Representative must authorize warranty service. Please contact the GF 

Customer Service department by calling 1.770.368.4700 or by e-mailing a request to [email protected]. Specific directions will be provided 

by the Customer Service Representative. Failure to abide by the specific directions will result in denial of the warranty claim.

Obtaining Warranty Service Outside the U.S.:

 The Purchaser must contact the Distributor from whom the product was purchased, 

commensurate with the guidelines set forth by that Distributor. Failure to abide by the specific directions will result in denial of the warranty 

claim.

EXCLUSIONS

The warranty does not cover and GF shall not be liable for the following:
1)  Defects, damage, or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, 

tampering or failure to seek and obtain repair or replacement in a timely manner;

2)  Products which are not installed, used, or properly cleaned and maintained as required in the official manual for the applicable product;
3)  Products considered to be of a consumable nature including, but not limited to: filters, fuses, gaskets and lubricants;
4)  Accessories or parts not provided by GF;
5)  Charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such 

products which are not expressly authorized in writing, in advance, by GF;

6)  Any shipping charges incurred in the replacement part installation or repair;
7)  Costs and expenses of regular maintenance and cleaning; and
8)  Representations and warranties made by any person or entity other than GF .

ENTIRE WARRANTY, EXCLUSIVE REMEDY AND CONSEQUENTIAL DAMAGES DISCLAIMER

THIS WARRANTY IS GF’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. GF MAKES NO IMPLIED 

WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IF ANY MODEL OR SAMPLE WAS SHOWN TO THE CUSTOMER, SUCH MODEL OR SAMPLE WAS USED MERELY TO ILLUSTRATE THE GENERAL 

TYPE AND QUALITY OF THE PRODUCT AND NOT TO REPRESENT THAT THE PRODUCT WOULD NECESSARILY CONFORM TO THE MODEL OR 

SAMPLE IN ALL RESPECTS.
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PARTS. GF SHALL NOT BE LIABLE FOR AND HEREBY 

DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO: 

DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER, OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, 

PAYMENTS AND BENEFITS.
CERTAIN STATES MAY CONFER ADDITIONAL RIGHTS REGARDING WARRANTIES AND IN THOSE STATES GF’S LIABILITY AND THE LIABILITY OF 

GF’S SUPPLIERS, SHALL BE LIMITED TO THE FULLEST EXTENT PERMITTED BY LAW. 
The warranties contained herein, together with GF’s Terms and Conditions, found on GF’s website and which may be updated from time to 

time, contain all the representations and warranties with respect to the subject matter of this document, and supersede all prior negotiations, 

agreements and understandings with respect thereto. The recipient of this document hereby acknowledges and represents that it has not 

relied on any representation, assertion, guarantee, warranty, collateral contract or other assurance, except those set out in this document.
For additional information on this Hausted product or this warranty, please contact a GF Customer Service Representative.

NOTES:

1)  Additional terms and conditions may apply.
2)  Outward freight damage must be notated on the appropriate shipping documents. 
3)  Claims for any short shipment or concealed damage must be made within three (3) days of the invoice date.
4)  Additional international, federal and state regulations govern specific requirements for freight claims. Failure to abide by those 

regulations may result in a denial of the freight claim. GF will assist you in filing the freight claim.

Summary of Contents for Hausted HORIZON 4D2DPA

Page 1: ...IES MULTI PURPOSE STRETCHERS ELECTRIC POWERED MODELS 4E2DPA 4D2DPA OPERATING MANUAL READ THIS MANUAL BEFORE OPERATING YOUR STRETCHER SAVE THIS MANUAL FOR FUTURE USE THE MOST CURRENT VERSION OF THIS MANUAL CAN BE FOUND ONLINE AT WWW HAUSTED COM ...

Page 2: ...R OPERATION SEE DIAGRAM ON FOLLOWING PAGE 11 WARNINGS RELATED TO SERVICE AND REPAIR SEE DIAGRAM ON FOLLOWING PAGE 11 FEATURES SHOWN IN ILLUSTRATION OF 4E2DPAST BELOW 12 WARNINGS CAUTIONS AND PROPER OPERATION SEE LIST ON PREVIOUS PAGE 12 3 3 BRAKING AND STEERING OPERATION ALL MODELS 13 3 3 1 APPLYING THE BRAKES 13 3 3 2 RELEASING THE BRAKES 13 3 3 3 APPLYING THE STEERING LOCK FIFTH WHEEL 13 3 3 4 R...

Page 3: ...OR THE USER 24 6 OPTIONAL ACCESSORIES 25 7 GF HEALTH PRODUCTS INC LIMITED WARRANTY FOR HAUSTED BRAND STRETCHERS AND CHAIRS 26 8 DISPOSAL AND KEY TO SYMBOLS 27 DISPOSAL 27 KEY TO SYMBOLS 27 9 APPENDIX 28 9 1 GUIDANCE AND MANUFACTURER S DECLARATION ELECTROMAGNETIC EMISSIONS 28 9 2 ENCLOSURE PORT 1 28 9 3 ENCLOSURE PORT IMMUNITY TO RF WIRELESS COMMUNICATIONS EQUIPMENT 1 29 9 4 INPUT AC POWER PORT 1 3...

Page 4: ...nd proper unit operation This manual contains maintenance schedules and procedures which should be followed for satisfactory equipment performance We encourage you to contact GF Health Products Inc with maintenance concerns Advisory A listing of the safety precautions to be observed when operating and servicing this equipment can be found in Section 1 of this manual Do not operate or service the e...

Page 5: ...ndicates a potential hazard situation or unsafe practice that if not avoided could result in minor or moderate personal injury s NOTICE Indicates a potential hazard situation or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information to ensure that you get the most from your product DANGER WARNING CAUTION ...

Page 6: ...separate ON OFF switch WARNING Always disconnect the power source whenever troubleshooting or servicing any electric powered stretcher WARNING Do not modify the equipment without the authorization of the manufacturer WARNING This product can expose you to chemicals including Di 2 ethylhexyl phthalate DEHP which is known to the State of California to cause cancer or birth defects or other reproduct...

Page 7: ...quipment If adjacent or stacked use with other equipment is necessary this Hausted equipment and the other equipment should be observed to verify that they are operating normally WARNING The EMISSIONS characteristics of this equipment make it suitable for use in industrial areas and hospitals CISPR 11 class A If it is used in a residential environment for which CISPR 11 class B is usually required...

Page 8: ...o 90 30 C Atmospheric Pressure 700 to 1060 hPa UNPACKING INSTRUCTIONS IMPORTANT Follow each step in the order shown in these instructions Your Hausted equipment has been carefully packed at our manufacturing plant to ensure safe shipment to your medical facility There are several procedures you must follow to put your new equipment in service These procedures only take a few minutes to complete an...

Page 9: ...duct has a maximum weight capacity of 720 lb 326 kg EVENLY DISTRIBUTED Info All dimensions in the following drawings unless otherwise specified are in inches All dimensions are 375 GF Health Products Inc reserves the right to change specifications without notice Info Electrical specifications follow drawings ...

Page 10: ...ut Voltage 120V 60Hz Amperage Max 4 0A Duty Cycle 10 2 Min in 18 Min IP Rating IPX6 Grounding Protection Type B Electrical Specifications Applies to 4D2DPA Models Only Product Classification 1 Input Voltage 230V 50 60Hz Amperage Max 2 0A Duty Cycle 10 2 Min in 18 Min IP Rating IPX6 Grounding Protection Type B ...

Page 11: ...ended to be used to lower patient during EMERGENCY situations only G WARNING Ensure rail is locked before leaving patient H WARNING The lockout panel deactivates both the patient pendant and the control panel I WARNING Floors must be smooth and level to maintain optimum fifth wheel steering Fifth wheel steering functions can be influenced by floor irregularities bumps or dips greater than 1 2 13 m...

Page 12: ...HP_4E2 INS LAB RevA21 12 Features Shown in Illustration of 4E2DPAST below WARNINGS CAUTIONS AND PROPER OPERATION See List on Previous Page ...

Page 13: ...Fifth Wheel From any corner of the stretcher depress the green pedal downward into locked position Figure 3 3 Push the stretcher forward Either one caster at the foot end will lock into non swivel mode or the optional fifth wheel will lower and apply pressure to the floor thus guiding the stretcher along a straight path with minimal steering effort by the attendant WARNING Floors must be smooth an...

Page 14: ... pendant to rail when not in use Keep cord clear of moving parts 3 4 3 Plug Locations The plug is located under top section head end Figure 3 6 Unwrap cord from bracket and plug into the nearest wall receptacle Do not position the unit so that it is difficult to disconnect the plug WARNING All electric powered stretchers are equipped with a built in battery backup system but the unit should remain...

Page 15: ...r LED The unit is equipped with a low battery indicator LED located on the controller cover under the foot end of the stretcher Figure 3 7 When a button on the pendant is pressed and the LED illuminates it indicates that the backup batteries require charging Plug the unit into a wall receptacle 3 4 6 Charge Indicator Light Models after 1 20 2014 The charge indicator light is in the left bottom cor...

Page 16: ...st row of buttons on the pendant Figure 3 9 Hold until the desired incline is achieved Lowering Press the second button on the first row of buttons on the pendant Hold until the desired recline is achieved Simultaneous Back and Foot Section Adjustment Raise Back Section Foot Section Press the first button on the third row of buttons on the pendant Hold until the desired angle is achieved Lower Bac...

Page 17: ...instructions Pendant Trendelenburg Press and hold the second button on the bottom row of buttons Figure 3 12 until desired angle is achieved Pendant Reverse Trendelenburg Press and hold the first button on the bottom row of buttons Figure 3 13 until desired angle is achieved Figure 3 13 Figure 3 12 ...

Page 18: ...the same time press and hold the UP or DOWN arrow button which corresponds to the desired direction of travel Figure 3 17 until the desired Trendelenburg angle is achieved Simultaneous Back and Foot Section Adjustment Press and hold the third button from the right on the second row row 2 column 3 At the same time press and hold the UP or DOWN arrow button which corresponds to the desired direction...

Page 19: ...illuminated No light above a function means that function is unlocked and ready to use Back Section Lockout Press the Lockout Button simultaneously with the first button on the top row Figure 3 21 of the control panel Foot Section Lockout Press the Lockout Button simultaneously with the second button on the top row Figure 3 22 of the control panel Height Lockout Press the Lockout Button simultaneo...

Page 20: ...op rail tube from under litter top firmly then pull up Figure 3 25 until rail locks into full up position 3 6 2 Lowering the Rail Firmly grasp top of rail pull out on red tab under litter top at foot or head end Figure 3 26 and lower side rail completely under litter top WARNING Ensure both rails are in upright locked position before leaving patient Figure 3 25 Figure 3 26 ...

Page 21: ...Handles Hinge the push handle up Figure 3 28 until it stops Slide the push handle down into the socket until it stops Repeat process for handle on the other side Figure 3 29 3 7 2 Lowering the Push Handles Lift up on push handle and rotate Figure 3 28 until it is in the down position Figure 3 27 Repeat process for the other side ...

Page 22: ... screw collar or large screw collar until loosened adequately to allow inner tube to easily slide up or down within outside tube 2 Lift up on top of IV Rod until desired height is achieved 3 Tighten collar screw s until hand tight 3 8 3 Retracting IV Rod 1 Support extended portion of IV Rod with one hand 2 Rotate screw collar until loosened 3 Lower IV Rod until desired height is achieved then re t...

Page 23: ...ntroller 2 Check the pendant control plug connection at the controller 3 Ensure all lockout functions are deactivated 4 Contact GF Health Products Inc for further help and instruction The unit runs when plugged into wall receptacle but does not run on battery backup Step 1 Plug unit into a wall receptacle overnight If the batteries do not hold a charge replace the batteries section 4 2 GF Health P...

Page 24: ... ALWAYS follow manufacturer s recommended dilution Disinfectants for vinyl products Phenolic disinfectants are the best choice for vinyl Properly diluted quaternaries are also acceptable for vinyl Quaternary Isopropyl disinfectants ARE NOT recommended for vinyl Disinfectants for urethane products Quaternary disinfectants are recommended for urethane Quaternary Isopropyl disinfectants are recommend...

Page 25: ...Mobile IV Stand Attachment H12845000 Vertical Oxygen Tank Holder Assembly H06925700 Paper Roll Holder H06536600 Universal Patient Tray H07565600 Push Handle Assembly Bumpered H076540 Surgical Accessory Rail AirGlide H06774100 Side Rail Pads WARNING It is recommended that only accessories approved by GF Health Products Inc be used with this device The use of accessories transducers and cables other...

Page 26: ...reight damage tampering or failure to seek and obtain repair or replacement in a timely manner 2 Products which are not installed used or properly cleaned and maintained as required in the official manual for the applicable product 3 Products considered to be of a consumable nature including but not limited to filters fuses gaskets and lubricants 4 Accessories or parts not provided by GF 5 Charges...

Page 27: ...oduct Metal Scrap Cable Scrap Electronic Scrap Plastic Recycling or Combustion 4E2 X X X X 4D2 X X X X Info Lead acid batteries contained in the controller are recoverable resources and should be recycled KEY TO SYMBOLS The following symbols are used on Hausted product labels Protective Earth Manufacturer Earth Ground Keep Dry General Warning Sign Fragile Handle with Care CE Mark Electrical and El...

Page 28: ...magnetic fields d e IEC 61000 4 8 30 A m g 50 Hz or 60 Hz a The interface between the PATIENT physiological signal simulation if used and the ME EQUIPMENT or ME SYSTEM shall be located within 0 1 m of the vertical plane of the uniform field area in one orientation of the ME EQUIPMENT or ME SYSTEM b ME EQUIPMENT and ME SYSTEMS that intentionally receive RF electromagnetic energy for the purpose of ...

Page 29: ...ion 1 kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modulation b 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 870 930 1 720 1 700 1 990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation b 217 Hz 2 0 3 28 1 845 1 970 2 450 2 400 2 570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modula...

Page 30: ...current injection clamps shall be performed in a 150 Ω system d If the frequency stepping skips over an ISM or amateur band as applicable an additional test frequency shall be used in the ISM or amateur radio band This applies to each ISM and amateur radio band within the specified frequency range e Testing may be performed at other modulation frequencies identified by the RISK MANAGEMENT PROCESS ...

Page 31: ...cable to ME EQUIPMENT and ME SYSTEMS with RATED input current less than or equal to 16 A phase and ME EQUIPMENT and ME SYSTEMS with RATED input current greater than 16 A phase p Applicable to ME EQUIPMENT and ME SYSTEMS with RATED input current less than or equal to 16 A phase q At some phase angles applying this test to ME EQUIPMENT with transformer mains power input might cause an overcurrent pr...

Page 32: ...led with conductive liquids and intended to be connected to a PATIENT shall be considered to be PATIENT COUPLED cables If the frequency stepping skips over an ISM or amateur radio band as applicable an additional test frequency shall be used in the ISM or amateur radio band This applies to each ISM and amateur radio band within the specified frequency range The ISM industrial scientific and medica...

Page 33: ...ctor shells perform air discharge testing to the connector shell and the pins using the rounded tip finger of the ESD generator with the exception that the only connector pins that are tested are those that can be contacted or touched under conditions of INTENDED USE by the standard test finger shown in Figure 6 of the general standard applied in a bent or straight position f Capacitive coupling s...

Page 34: ... transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to...

Page 35: ...ion adjustment nurse control 18 Foot section lockout nurse control 19 H Hand pendant functions 16 Height adjustment 16 Height adjustment nurse control 18 Height lockout nurse control 19 I Indications for use 4 Info statement significance 5 Introduction 4 IV rod permanently mounted operation 22 IV rod retraction 22 L Limited warranty 26 Lockout nurse control 19 Low battery indicator light 15 Lubric...

Page 36: ...rahamfield com 2014 GF Health Products Inc All Rights Reserved Airglide Hausted and Horizon are trademarks of GF Health Products Inc One Graham Field Way Atlanta GA 30340 3140 USA GF Health Products Inc is an ISO 13485 2016 MDSAP Certified Company www hausted com www grahamfield com Manufactured by GF Health Products Inc One Graham Field Way Atlanta GA 30340 3140 ...