5. Control and machine cabinet
15 / 54
The electrical connection of the switch cabinet must only be carried out by a
qualified electrician.
EPP switch cabinet for indoor installation
(380 x 580 x 300 mm)
The EPP machine cabinet is secured to a wall with the hanger bolts
supplied. The hanger bolts should be secured to the wall horizontally
using dowels spaced 280 mm apart. The cabinet is then affixed to them
and secured with wing nuts.
When choosing where to install the cabinet, note that the hose connec-
tions are on the underside of the cabinet.
Metal cabinet for indoor installation
(500 x 500 x 300 mm)
The machine cabinet is prepared for mounting on the wall. The wall
brackets provided must be attached to the rear of the cabinet first.
There must be a 230 V socket (16A, slow blow) near the cabinet.
The mains supply with a main switch and ventilation grille are located
on the right-hand side. The hose connections and another ventilation
grille can be found on the right.
Large systems for more than 40 inhabitants are supplied with a two-door cabinet for installing on
the ground.
Systems for 75 or more inhabitants, running on a 3-phase current of 380 V, must be connected
by an electrician as shown in the terminal diagram provided. Be sure that the compressor is
rotating in the right direction.
Fuse con-
nections!