Service
3A2799C
9
Service
Disassembly for Repair or
Cleaning
NOTE:
If replacing only the needle and seat, step 4 and
5 are not required. However, removing them allows you
to clean the gun more thoroughly.
1.
Relieve pressure.
2.
Disconnect the fluid hose (A) and swivel (if used).
Remove the tip guard (9). Unscrew the spring screw
(21) about 1/4 in. (7 mm) to release spring tension.
See F
IG
. 5.
3.
Unscrew the valve seat (2a). Remove the
gasket (2b). See F
IG
. 6.
4.
Remove one e-clip (26) then push the pin (18) out of
the gun. Remove the screw (13), pivot pin (23), and
trigger (24). See F
IG
. 7.
To reduce the risk of serious injury from fluid injection
or splashing, always follow the
Pressure Relief Proce-
dure
on page 5 before servicing the gun.
F
IG
. 5
9
21
A
ti19266a
Swivel
F
IG
. 6
F
IG
. 7
2b
2a
ti19270a
18
13
24
26
23
ti19271a
26