Technical Data
334513A
51
Technical Data
Wolverine Chemical Injection Pump
US
Metric
Maximum fluid working pressure
Varies by model. See
on page 3.
Input Voltage
CI-12X-XXX-XXX-X
12 VDC
CI-1AX-XXX-XXX-X
115 VAC
CI-2AX-XXX-XXX-X
230 VAC
CI-4AX-XXX-XXX-X
230 VAC or 460 VAC 3 Phase
Input Current
CI-12S-XXX-XXX-X
11 A maximum (small motor)
CI-12L-XXX-XXX-X
16 A maximum (large motor)
CI-1AX-XXX-XXX-X
2.0 A
CI-2AX-XXX-XXX-X
1.2 A
CI-4AX-XXX-XXX-X
0.59 A @ 230 VAC 3 Phase
CI-4AX-XXX-XXX-X
0.30 A @ 460 VAC 3 Phase
Power Connection
Environmental temperature range
-40°–176°F
-40°–80°C
Noise (dBa)
Maximum sound pressure
<70 dBa
Inlet/Outlet Sizes
Fluid inlet size
1/4 in. npt(f)
Fluid outlet size
1/4 in. npt(f)
Materials of Construction
Pump/Check Valve Seal Material
See
Configuration Chart
on page 15 for seal material. All
other packing materials are PEEK and PTFE unless other-
wise noted.
Wetted Parts
See
Configuration Chart
on page 15 for plunger material.
All other materials are 316 stainless steel unless otherwise
noted.
Weight
Wolverine Basic
31 lb.
14 kg
Wolverine Advanced Simplex
35 lb.
16 kg
Wolverine Advanced Duplex
39 lb.
18 kg