Appendix B - Data Exchange Interface
3A5186B
19
Pointer
De
signat
ion
Description
Comments
Read/
Write
91
Read Pump A Resettable Mate-
rial counter
In selected mass units, times 10. So, for instance, if in Kg mode,
101 = 10.1 Kg.
read
92
Read Pump B Resettable Mate-
rial counter
read
93
Reset Pump A Resettable mate-
rial counter
No Data required for Data Exchange Interface Output Value
location (Same as pressing
on the corresponding setup or
run screen).
Write
94
Reset Pump B Resettable mate-
rial counter
Write
95
Read Pump A Resettable Cycle
counter
In whole pump cycle units of measure.
read
96
Read Pump B Resettable Cycle
counter
read
97
Reset Pump A Resettable Cycle
counter
No Data required for Data Exchange Interface Output Value
location (Same as pressing
on the corresponding setup or
run screen).
Write
98
Reset Pump B Resettable Cycle
counter
Write
99-100 Reserved for Future Use
101
Get Heat Soak Timer A
Get Primary or Secondary Heat Soak timer Remaining Count in
Seconds (= 0 if not active)
Read
102
Get Heat Soak Timer B
Read
103 -
110
Reserved for Future Use
111
Get CV Percent (5051 = 50.51%) Get Control Variable for Pump, Primary Heat Zone
Read
112
Get CV Percent (5051 = 50.51%) Get Control Variable for Platen, Primary Heat Zone
Read
113
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 1, Primary
Read
114
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 2, Primary
Read
115
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 3, Primary
Read
116
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 4, Primary
Read
117
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 5, Primary
Read
118
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 6, Primary
Read
119
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 7, Primary
Read
120
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 8, Primary
Read
121
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 9, Primary
Read
122
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 10, Primary
Read
123
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 11, Primary
Read
124
Get CV Percent (5051 = 50.51%) Get Control Variable for Heat Zone 12, Primary
Read