Appendix A - I/O Signal Descriptions
14
3A5186B
Status Word 2 Indication Bits
System Control Bits
The following table reflects the bit variables in output instance 4, which can be set or cleared to control the following
conditions.
1
Same as pressing
on the main Run screen.
2
Same as pressing
on the main Run screen.
3
Same as pressing
on the main Run screen.
4
Same as pressing
on the main Run screen.
5
Same as pressing
or
on the main Run screen.
Bit
Number
Hex
Equivalent
Binary Number
Description
0
0x0001
0000 0000 0000 0001
Heat Soak Timer Active for Primary (A) System
1
0x0002
0000 0000 0000 0010
Heat Soak Timer Active for Secondary (B) System
2
0x0004
0000 0000 0000 0100
Turn ON Primary System (A), Heat Command Active
3
0x0008
0000 0000 0000 1000
Turn ON Secondary System (B), Heat Command Active
4
0x0010
0000 0000 0001 0000
Prime/Pump on A Command Active
5
0x0020
0000 0000 0010 0000
Prime/Pump on B Command Active
6
0x0040
0000 0000 0100 0000
Setback A Command Active
7
0x0080
0000 0000 1000 0000
Setback B Command Active
8
0x0100
0000 0001 0000 0000
Cross Over Command Active
9
0x0200
0000 0010 0000 0000
PLC Control Active Indication
10
0x0400
0000 0100 0000 0000
Heart Beat Indication for PLC from TOF (
See Note 7 in
System
Control Bits
)
11
0x0800
0000 1000 0000 0000
Error/Event Reported is an Alarm
12-15
------
------
Reserved for Future Use
Bit
Number
Hex
Equivalent
Binary Number
Description
Notes
0
0x0001
0000 0000 0000 0001 Turn ON Heat Command for System A Command
1
1
0x0002
0000 0000 0000 0010 Turn ON Head Command for System B Command
1
2
0x0004
0000 0000 0000 0100 Turn ON/Prime Pumps for System A Command
2
3
0x0008
0000 0000 0000 1000 Turn ON/Prime Pumps for System B Command
2
4
0x0010
0000 0000 0001 0000 Setback Command System A
3
5
0x0020
0000 0000 0010 0000 Setback Command System B
3
6
0x0040
0000 0000 0100 0000 Cross Over Command
4
7
0x0080
0000 0000 1000 0000 Pause Material Tracking/Counters Command
5
8
0x0100
0000 0001 0000 0000 Continue Material Tracking Command
5
9
0x0200
0000 0010 0000 0000 Command Setpoint Indications on Map for System B
6
10
0x0400
0000 0100 0000 0000 Command Setback Setpoint Indications for System B
6
11
0x0800
0000 1000 0000 0000 Heart Beat Output to TOF
7
12
0x1000
0001 0000 0000 0000 PLC Control Command
8
13-15
------
------
Reserved for Future Use