Troubleshooting
26
3A7656C
Pump output is low
Pump rod damage.
Replace Pump if necessary.
See
Low stall pressure.
Turn pressure knob fully
clockwise. Make sure Pressure
Control Knob is properly
installed to allow full clockwise
position. If problem persists,
replace control assembly. See
Piston packings are worn or
damaged.
Replace Pump if necessary.
See
O-ring in Pump is worn or
damaged.
Replace Pump if necessary.
See
Large pressure drop in hose
with heavy materials.
Reduce overall length of hose.
Check extension cord for
correct size.
Motor runs but Pump does not
stroke
Connecting rod assembly
damaged.
Replace Motor and Drive
assembly. See
Gears or drive housing
damaged.
Inspect drive housing
assembly and gears for
damage. Replace Motor and
Drive assembly if necessary.
See
Excessive material leakage
into throat packing nut
Throat packing nut is loose.
Remove throat packing nut
spacer. Tighten throat packing
nut just enough to stop
leakage.
Throat packings are worn or
damaged.
Replace Pump assembly. See
Displacement rod is worn or
damaged.
Replace Pump assembly. See
Fluid is spitting from Spray
Gun
Air in Pump or hose.
Check and tighten all fluid
connections. Cycle Pump as
slowly as possible during
priming.
Fluid supply is low or empty.
Refill fluid supply. Prime Pump.
Check fluid supply often to
prevent running Pump dry.
Problem
What to Check
If check is OK, go to next
check
What to Do
When check is not OK,