Maintenance
3A7656C
23
Maintenance
Routine maintenance is important to ensure
proper operation of your sprayer.
Perform
12, before performing maintenance.
Activity
Interval
Inspect/clean Inlet Strainer.
Daily or each time you spray
Inspect motor shield vents for blockage.
Daily or each time you spray
Check sprayer stall.
With Spray Gun NOT triggered, sprayer motor should stall
and not restart until Spray Gun is triggered again.
If sprayer starts again with Spray Gun NOT triggered,
inspect Pump for internal/external leaks and check
Prime/Spray Valve for leaks.
Every 1000 gallons (3785 liters)
Throat packing adjustment
When Pump packing begins to leak after extended use,
tighten packing nut down until leakage stops or lessens.
This allows approximately 100 gallons of additional
operation before a repacking is required. Packing nut can
be tightened without O-ring removal.
As necessary based on usage