Electronic Control System
311163ZAH
27
Automatic Evacuation of the Bin
1. On the Operator Interface, select TAR-
GET/ACTUAL RUN screen.
2. Ram plate seal inflates.
3. Ram down air pressure is applied and pumps start
in slow mode, then switches to fast mode.
4. When the low limit setting is reached, the pumps
switch to slow mode for 2 minutes and then stop.
5. The ram plate seal deflates and the ram is raises.
Unloading the Bin
1. Follow the
, page 24.
2. Ensure seal is deflated and ram is raised.
3. Unload the bin from the frame.
System Shutdown
Follow the
, page 24.
Depending on the type of material, it may be best to
deflate the seal and raise the ram plate out of the mate-
rial or keep the ram plate lowered in the bin. Some
materials dry and harden when exposed to air. Cover
materials when they are not being used.
Press arrow
to select RUN and press ENT.
TARGET
1000
LBS RUN
ACTUAL
0000
LBS EXIT