INSTALLATION & SERVICE INFORMATION

Pump Design:

3 chamber diaphragm

Motor Design:

Permanent magnet DC 

Voltages:

12, 24 VDC, 115 VAC

Pump Rating:

IP 54 (splash proof)

Max. Amp. Draw:

12 VDC: 9 amps
24 VDC: 6 amps

115 VAC: 3 amps

Pump Head: 

Polypropylene 

Elastomers:

Diaphragm

Geolast, Santoprene

TM

Check valves

EPDM, Viton

®

Max. Flow Rate:

4 GPM (15.1 LPM)

Max. Pressure:

60 psi (4.1 bar) switch cutoff

50 psi (3.4 bar) max running pressure

Liquid Temp:

40° F (4° C) Min*

140° F (60° C) Max*

Duty Cycle:

Intermittent**

Weight: 

5.05 lbs ( 2.29 kg) max.

Wiring Options:

Standard 18 AWG leads

Plug-in Ports:

1/2” (12.7 mm)

SPECIFICATIONS

FLOJET Triplex High Flow Series pumps are designed for a wide
range  of  applications  and  are  constructed  from  a  selection  of
materials suitable for handling a broad range of chemicals. The
Triplex  High  Flow  pumps  are  self-priming  and  can  run  dry
without harm. They are intended for intermittent duty cycles but
can be run continuously for a short periods of time. The higher
the duty cycle, the shorter the expected life of the pump. Typical
uses  include  transfer,  delivery,  spraying,  cooling,  filtration,
dispensing, and pressure boosting.

Models equipped with an external bypass system are designed
to pump at high pressures while at low or high flow rates. Models
equiped with bypass only must be turned off/on manually, or by
an independent control device. Models equipped with a bypass
only will continue to run until the power is manually turned off.
The  Triplex  High  Pressure  pumps  are  not  recommended  for
continuous  duty  service  due  to  limited  motor  brush  life.
Operation  at  lower  pressures  and  temperatures,  however,  will
extend overall pump service life.

BYPASS OPERATION (if equipped)

Pump  models  fitted  with  a  pressure  switch  are  known  as
demand  pumps.  The  pressure  switch  is  preset  to  shut  off  the
pump motor automatically when a specific pressure is reached,
such  as  in  closed  discharge  conditions.  The  pressure  switch
turns the pump motor on automatically as the pressure drops,
such  as  when  the  discharge  is  opened.  Demand  operation  is
considered  an  “intermittent  duty”  application.  The  maximum
intermittent  duty  cycle  is  that  which  will  cause  the  motor  to
reach its maximum thermal limits. Once the maximum thermal
limit is reached, the motor must be allowed to settle to a lower
(ideally  ambient)  temperature, before  resuming  operation.
Running the pump at or near the maximum thermal limit for an
extended  period  of  time  will  shorten  the  life  of  the  pump  and
may  result  in  immediate  pump  failure.  Demand  pump  models
feature an integral pressure switch that automatically turns the
pump off/on in response to open/closed discharge conditions.

DEMAND OPERATION (intermittent duty)

Allow pump to prime with discharge line (or spray valve) open, to
avoid  airlock.  Built-in  pressure  switch  will  shut  off  pump
automatically  when  discharge  valve  is  closed  and  will  restart
pump when valve is opened. When pump runs out of liquid, it
will continue to operate. Running dry will not damage the pump.
Turn off manually.

OPERATION

* Consult factory for higher fluid temperature options

**

***

 C

Consult factory for other type of port fittings

onsult factory for continuous duty application

Model R3521 / 03521 Series

High Flow Triplex Pump